Radiative Cooling Limits Collisional Heating of Large Ions

Abstract Activation of ions inside a mass spectrometer to induce dissociation or conformational changes can be a powerful way to investigate their structure. Although the most common way to activate ions in contemporary instruments is by collisions with a neutral buffer gas, ions also constantly exchange photons with the ambient radiation field of the instrument. In blackbody infrared radiative dissociation (BIRD) experiments performed in Fourier-transform ion cyclotron resonance or ion trap instruments at low pressure, radiative energy exchange alone can be sufficient to dissociate or unfold ions on the upper-millisecond to several-minute timescale, depending on the thermochemical barrier and radiation temperature. Collisional activation, as implemented in most commercial platforms, typically occurs on the microsecond- to few-millisecond timescale, a roughly thousandfold shorter kinetic window than in BIRD experiments. Radiative energy exchange effects on collisional heating and cooling for large biomolecular ions in these experiments are poorly understood, and computing radiative energy exchange rates for ions >∼1 MDa has been intractable due to the enormous density of states of these ions. Here, we introduce an algorithm for computing radiative energy exchange rates for large ions as a function of ion mass, composition, and initial vibrational temperature. Scaling of radiative emission rates with ion size and vibrational temperature, and the competition between radiative cooling and collisional heating, are studied by incorporating results from this algorithm into the IonSPA software. Implications for thermochemical CID/CIU barrier determination for large ions and practical limitations for collisional heating of multi-MDa- to GDa-sized ions in charge detection mass spectrometry are also discussed.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2026-11-14
DOI
https://doi.org/10.1021/jasms.6c00376
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Radiative Cooling Limits Collisional Heating of Large Ions

Evan R. Williams, Zachary M. Miller, James S. Prell, Austin W. Green
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
article

Radiative Cooling Limits Collisional Heating of Large Ions

Evan R. Williams, Zachary M. Miller, James S. Prell, Austin W. Green
article en

Abstract

Abstract Activation of ions inside a mass spectrometer to induce dissociation or conformational changes can be a powerful way to investigate their structure. Although the most common way to activate ions in contemporary instruments is by collisions with a neutral buffer gas, ions also constantly exchange photons with the ambient radiation field of the instrument. In blackbody infrared radiative dissociation (BIRD) experiments performed in Fourier-transform ion cyclotron resonance or ion trap instruments at low pressure, radiative energy exchange alone can be sufficient to dissociate or unfold ions on the upper-millisecond to several-minute timescale, depending on the thermochemical barrier and radiation temperature. Collisional activation, as implemented in most commercial platforms, typically occurs on the microsecond- to few-millisecond timescale, a roughly thousandfold shorter kinetic window than in BIRD experiments. Radiative energy exchange effects on collisional heating and cooling for large biomolecular ions in these experiments are poorly understood, and computing radiative energy exchange rates for ions >∼1 MDa has been intractable due to the enormous density of states of these ions. Here, we introduce an algorithm for computing radiative energy exchange rates for large ions as a function of ion mass, composition, and initial vibrational temperature. Scaling of radiative emission rates with ion size and vibrational temperature, and the competition between radiative cooling and collisional heating, are studied by incorporating results from this algorithm into the IonSPA software. Implications for thermochemical CID/CIU barrier determination for large ions and practical limitations for collisional heating of multi-MDa- to GDa-sized ions in charge detection mass spectrometry are also discussed.

Journal of the American Society for Mass Spectrometry
University of Oregon (US), University of California System (US)
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon