Does ceiling‐fan use modify circulating markers of heat‐related stress in bed‐resting older adults?

Abstract Ceiling fans are a low‐energy strategy for reducing heat strain, but their ability to protect against subclinical cellular and organ stress is unknown. We examined circulating stress biomarkers in 20 older adults (12 females; median age 71 years), who completed randomized 8 h exposures to 31°C and 45% relative humidity while remaining reclined beneath a ceiling fan delivering 0 m s −1 (control) or 1.5 m s −1 (fan). Venous blood was collected before and after each exposure and analysed for serum intestinal fatty acid‐binding protein (IFABP), soluble cluster of differentiation 14 (sCD14), kidney injury molecule‐1, neutrophil gelatinase‐associated lipocalin, tumour necrosis factor‐α, interleukin‐6 and C‐reactive protein. Core temperature and heart rate were measured continuously. Biomarker responses were assessed using baseline‐adjusted linear mixed‐effects models with Holm correction for multiple testing. Fan use lowered peak core temperature and heart rate by 0.2°C ( P < 0.001) and 5 beats min −1 ( P = 0.030), respectively. The adjusted difference in IFABP change between control and fan was 344 pg mL −1 [95% confidence interval: 102–586] (unadjusted P = 0.005; Holm‐adjusted P = 0.035). Across conditions, the estimated changes in IFABP and sCD14 were 240 pg mL −1 [95% confidence interval: 11–468] (Holm‐adjusted P = 0.240) and 0.57 ng mL −1 [95% confidence interval: 0.10–1.03] (Holm‐adjusted P = 0.119), respectively. No other biomarker comparisons remained significant after Holm adjustment. Ceiling‐fan use at 31°C attenuated the IFABP response in bed‐resting older adults despite modest effects on core temperature and heart rate. These exploratory findings suggest that fan‐mediated protection might extend beyond changes captured by conventional physiological measures, but confirmation in prospectively powered studies incorporating direct measures of gastrointestinal permeability is required.

Authors

Institutions

Publication Details

Journal
Experimental Physiology
Published
2026-11-14
DOI
https://doi.org/10.1113/ep094380
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Does ceiling‐fan use modify circulating markers of heat‐related stress in bed‐resting older adults?

Glen Patrick Kenny, Fergus K. O’Connor, James J. McCormick, Kelli E. McCormick
Experimental Physiology
Thermoregulation and physiological responses
article

Does ceiling‐fan use modify circulating markers of heat‐related stress in bed‐resting older adults?

Glen Patrick Kenny, Fergus K. O’Connor, James J. McCormick, Kelli E. McCormick
article en

Abstract

Abstract Ceiling fans are a low‐energy strategy for reducing heat strain, but their ability to protect against subclinical cellular and organ stress is unknown. We examined circulating stress biomarkers in 20 older adults (12 females; median age 71 years), who completed randomized 8 h exposures to 31°C and 45% relative humidity while remaining reclined beneath a ceiling fan delivering 0 m s −1 (control) or 1.5 m s −1 (fan). Venous blood was collected before and after each exposure and analysed for serum intestinal fatty acid‐binding protein (IFABP), soluble cluster of differentiation 14 (sCD14), kidney injury molecule‐1, neutrophil gelatinase‐associated lipocalin, tumour necrosis factor‐α, interleukin‐6 and C‐reactive protein. Core temperature and heart rate were measured continuously. Biomarker responses were assessed using baseline‐adjusted linear mixed‐effects models with Holm correction for multiple testing. Fan use lowered peak core temperature and heart rate by 0.2°C ( P < 0.001) and 5 beats min −1 ( P = 0.030), respectively. The adjusted difference in IFABP change between control and fan was 344 pg mL −1 [95% confidence interval: 102–586] (unadjusted P = 0.005; Holm‐adjusted P = 0.035). Across conditions, the estimated changes in IFABP and sCD14 were 240 pg mL −1 [95% confidence interval: 11–468] (Holm‐adjusted P = 0.240) and 0.57 ng mL −1 [95% confidence interval: 0.10–1.03] (Holm‐adjusted P = 0.119), respectively. No other biomarker comparisons remained significant after Holm adjustment. Ceiling‐fan use at 31°C attenuated the IFABP response in bed‐resting older adults despite modest effects on core temperature and heart rate. These exploratory findings suggest that fan‐mediated protection might extend beyond changes captured by conventional physiological measures, but confirmation in prospectively powered studies incorporating direct measures of gastrointestinal permeability is required.

Experimental Physiology
Griffith University (AU), University of Ottawa (CA), Ottawa Hospital (CA), Prince Charles Hospital (AU), Ottawa University (US)
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon