Simulation-based techno-economic evaluation of triboelectric and electromagnetic footstep energy harvesting

Abstract Footstep energy harvesters must be evaluated by stored energy, mechanical input, power-management losses, and cost rather than by open-circuit voltage alone. This study developed a reproducible simulation framework for comparing electromagnetic, triboelectric, and hybrid floor-tile energy harvesters under a common 7.0 J gross footstep-energy budget. A reduced-order two-dimensional Finite Element Method Magnetics (FEMM) model, coil/load optimization, rectifier modeling, mechanical-energy checks, and an upfront prototype component-cost model were used for the electromagnetic generator (EMG). A nylon/polytetrafluoroethylene (PTFE) contact-separation triboelectric nanogenerator (TENG) was audited for active area, air breakdown, parasitic capacitance, leakage, high-voltage (HV) rectification, and shared mechanical input. The balanced EMG design used a 28-magnet alternating-radial array, American Wire Gauge (AWG) 32 coil with 1226 turns, Schottky rectification, and a modeled gear-ratio-80 scenario, producing 0.5507 J per simulated step and 0.00331 J per step per USD. A unit-consistent Paschen calculation gave a 19.48 kV uniform-field limit for the 5 mm TENG case; the audited TENG stored 0.002382 J per cycle. With one TENG cycle per EMG step, a realistic EMG-primary hybrid stored 0.552620 J per step, increasing stored energy by 0.346% but reducing energy per upfront dollar to 0.00214 J per step per USD. An illustrative coupling sensitivity showed that an additional mechanical penalty above 0.346% would erase this energy increment. A literature-bounded non-contact rotational TENG benchmark stored 0.001487 J per step under explicitly transferred assumptions; its mechanical allocation was not estimated because matching torque and mechanical-input data were unavailable. Under the modeled contact-separation geometry, conditioning assumptions, shared mechanical input, and prototype cost model, the studied TENG did not provide sufficient incremental stored energy to justify its addition for energy generation; this architecture-specific result does not generalize to all TENG designs.

Authors

Publication Details

Journal
Discover Electronics
Published
2026-11-15
DOI
https://doi.org/10.1007/s44291-026-00315-7
Primary Topic
Innovative Energy Harvesting Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Simulation-based techno-economic evaluation of triboelectric and electromagnetic footstep energy harvesting

Vivek Nadella, Ishaan Ghai, Vismay Patel
Discover Electronics
Innovative Energy Harvesting Technologies
article

Simulation-based techno-economic evaluation of triboelectric and electromagnetic footstep energy harvesting

Vivek Nadella, Ishaan Ghai, Vismay Patel
article en

Abstract

Abstract Footstep energy harvesters must be evaluated by stored energy, mechanical input, power-management losses, and cost rather than by open-circuit voltage alone. This study developed a reproducible simulation framework for comparing electromagnetic, triboelectric, and hybrid floor-tile energy harvesters under a common 7.0 J gross footstep-energy budget. A reduced-order two-dimensional Finite Element Method Magnetics (FEMM) model, coil/load optimization, rectifier modeling, mechanical-energy checks, and an upfront prototype component-cost model were used for the electromagnetic generator (EMG). A nylon/polytetrafluoroethylene (PTFE) contact-separation triboelectric nanogenerator (TENG) was audited for active area, air breakdown, parasitic capacitance, leakage, high-voltage (HV) rectification, and shared mechanical input. The balanced EMG design used a 28-magnet alternating-radial array, American Wire Gauge (AWG) 32 coil with 1226 turns, Schottky rectification, and a modeled gear-ratio-80 scenario, producing 0.5507 J per simulated step and 0.00331 J per step per USD. A unit-consistent Paschen calculation gave a 19.48 kV uniform-field limit for the 5 mm TENG case; the audited TENG stored 0.002382 J per cycle. With one TENG cycle per EMG step, a realistic EMG-primary hybrid stored 0.552620 J per step, increasing stored energy by 0.346% but reducing energy per upfront dollar to 0.00214 J per step per USD. An illustrative coupling sensitivity showed that an additional mechanical penalty above 0.346% would erase this energy increment. A literature-bounded non-contact rotational TENG benchmark stored 0.001487 J per step under explicitly transferred assumptions; its mechanical allocation was not estimated because matching torque and mechanical-input data were unavailable. Under the modeled contact-separation geometry, conditioning assumptions, shared mechanical input, and prototype cost model, the studied TENG did not provide sufficient incremental stored energy to justify its addition for energy generation; this architecture-specific result does not generalize to all TENG designs.

Discover ElectronicsVol. 3(1)
Innovative Energy Harvesting Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon