Feasibility and preliminary validation of a wearable sweat lactate sensor during incremental and steady-state exercise in trained runners

Lactate measurement is a cornerstone in the assessment of metabolic stress during exercise. However, blood sampling is invasive and impractical in applied contexts. In this context, sweat has emerged as a promising biological matrix for continuous and non-invasive monitoring of biomarkers, although the validity and reliability of sweat lactate remain controversial. To evaluate the feasibility and preliminary reliability of a new portable sweat lactate sensor, comparing its performance with capillary blood lactate during an incremental protocol and a rectangular protocol in trained runners. Nine trained runners performed either incremental or constant load exercise tests on a treadmill. Lactate was measured simultaneously in capillary blood using the conventional lactate strip, and in sweat using a both a customized wearable sensor and ion chromatography as a reference method. Kinetics, relative differences, correlations and linear regression models between methods were analyzed. Sweat lactate was consistently higher than blood lactate in both protocols. During the incremental test, very high correlations were observed between blood lactate and sweat lactate measured with the sensor (r = 0.979; R² = 0.959; p < 0.0001), with parallel kinetics and a clear linear relationship. In the rectangular test, correlations were moderate to high (r = 0.539–0.988), although with greater interindividual variability. The differences between the sensor and ion chromatography were small compared to the blood–sweat differences. This pilot study demonstrates that the wearable sensor is capable of continuously and consistently detecting lactate dynamics in sweat, especially during incremental exercise. Although absolute quantification remains limited by sweat variability, noninvasive monitoring of lactate in sweat exhibit high potential as a complementary tool for monitoring metabolic stress during exercise.

Authors

Institutions

Publication Details

Journal
Performance Enhancement & Health
Published
2026-11-14
DOI
https://doi.org/10.1016/j.peh.2026.100476
Primary Topic
Cardiovascular and exercise physiology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Feasibility and preliminary validation of a wearable sweat lactate sensor during incremental and steady-state exercise in trained runners

Francisco Javier Martínez-Noguera, Cristian Marín‐Pagán, Ramiro Alonso-Salinas, Pedro Enrique Alcaraz et al.
Performance Enhancement & Health
Cardiovascular and exercise physiology
article

Feasibility and preliminary validation of a wearable sweat lactate sensor during incremental and steady-state exercise in trained runners

Francisco Javier Martínez-Noguera, Cristian Marín‐Pagán, Ramiro Alonso-Salinas, Pedro Enrique Alcaraz, María Cuartero, Xing Xuan, Daniel Rojas, Gastón A. Crespo, Sofia Abud Zientek
article en

Abstract

Lactate measurement is a cornerstone in the assessment of metabolic stress during exercise. However, blood sampling is invasive and impractical in applied contexts. In this context, sweat has emerged as a promising biological matrix for continuous and non-invasive monitoring of biomarkers, although the validity and reliability of sweat lactate remain controversial. To evaluate the feasibility and preliminary reliability of a new portable sweat lactate sensor, comparing its performance with capillary blood lactate during an incremental protocol and a rectangular protocol in trained runners. Nine trained runners performed either incremental or constant load exercise tests on a treadmill. Lactate was measured simultaneously in capillary blood using the conventional lactate strip, and in sweat using a both a customized wearable sensor and ion chromatography as a reference method. Kinetics, relative differences, correlations and linear regression models between methods were analyzed. Sweat lactate was consistently higher than blood lactate in both protocols. During the incremental test, very high correlations were observed between blood lactate and sweat lactate measured with the sensor (r = 0.979; R² = 0.959; p < 0.0001), with parallel kinetics and a clear linear relationship. In the rectangular test, correlations were moderate to high (r = 0.539–0.988), although with greater interindividual variability. The differences between the sensor and ion chromatography were small compared to the blood–sweat differences. This pilot study demonstrates that the wearable sensor is capable of continuously and consistently detecting lactate dynamics in sweat, especially during incremental exercise. Although absolute quantification remains limited by sweat variability, noninvasive monitoring of lactate in sweat exhibit high potential as a complementary tool for monitoring metabolic stress during exercise.

Performance Enhancement & HealthVol. 15(1)
Universidad Católica de Murcia (ES), KTH Royal Institute of Technology (SE)
Agencia Estatal de Investigación
Good health and well-being
Cardiovascular and exercise physiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon