A COMPARATIVE EVALUATION OF DIFFERENT FERRULE DESIGNS ON THE FRACTURE RESISTANCE OF RESTORATIONS OVER POST AND CORE TREATED PREMOLARS WITH PRE-FABRICATED FIBER POST: AN IN-VITRO STUDY

Background: The ferrule effect reinforces endodontically treated teeth restored with post-and-core systems, yet evidence on how ferrule wall height and location affect fracture resistance remains limited. This study evaluated the influence of different ferrule designs on fracture resistance and failure patterns of post- and core-treated mandibular premolars restored with prefabricated fiber posts. Materials and Methods: Forty-two extracted mandibular premolars were endodontically treated and randomly divided into three groups (n=14): Group A, 2 mm circumferential ferrule (control); Group B, 2 mm buccal/1 mm lingual ferrule; Group C, 1 mm buccal/2 mm lingual ferrule. All specimens received fiber posts, composite cores, and zirconia crowns, followed by thermocycling. Fracture resistance was measured using a Universal Testing Machine; failure modes were assessed visually, by stereomicroscopy, and by SEM. Data were analyzed using one-way ANOVA with post hoc Tukey's test (p < 0.05). Results: Mean fracture resistance was highest in Group B (49.03 ± 22.90 N), followed by Group C (42.43 ± 21.11 N) and Group A (40.08 ± 11.32 N), with significant differences among all groups (p < 0.05–0.001). Failure mode analysis showed significant differences in fractures below the bone level and vertical root fractures across groups (p < 0.05). Conclusion: Ferrule configuration significantly affects fracture resistance of post- and core-treated premolars. A buccally dominant ferrule design (2 mm buccal, 1 mm lingual) provided greater fracture resistance than the conventional circumferential and lingually dominant configurations, suggesting a biomechanical advantage relevant to restorative decision-making in teeth with asymmetric coronal structure loss.

Authors

Institutions

Publication Details

Journal
International Journal of Drug Delivery Technology
Published
2026-11-14
DOI
https://doi.org/10.25258/ijddt.16.88s.154
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A COMPARATIVE EVALUATION OF DIFFERENT FERRULE DESIGNS ON THE FRACTURE RESISTANCE OF RESTORATIONS OVER POST AND CORE TREATED PREMOLARS WITH PRE-FABRICATED FIBER POST: AN IN-VITRO STUDY

Dayanand Huddar, Raghavendra Adaki, Rohit Dhole, Banashree C Pattanshetti et al.
International Journal of Drug Delivery Technology
Dental materials and restorations
article

A COMPARATIVE EVALUATION OF DIFFERENT FERRULE DESIGNS ON THE FRACTURE RESISTANCE OF RESTORATIONS OVER POST AND CORE TREATED PREMOLARS WITH PRE-FABRICATED FIBER POST: AN IN-VITRO STUDY

Dayanand Huddar, Raghavendra Adaki, Rohit Dhole, Banashree C Pattanshetti, Simran A Dewani, Deepti S Fulari
article en

Abstract

Background: The ferrule effect reinforces endodontically treated teeth restored with post-and-core systems, yet evidence on how ferrule wall height and location affect fracture resistance remains limited. This study evaluated the influence of different ferrule designs on fracture resistance and failure patterns of post- and core-treated mandibular premolars restored with prefabricated fiber posts. Materials and Methods: Forty-two extracted mandibular premolars were endodontically treated and randomly divided into three groups (n=14): Group A, 2 mm circumferential ferrule (control); Group B, 2 mm buccal/1 mm lingual ferrule; Group C, 1 mm buccal/2 mm lingual ferrule. All specimens received fiber posts, composite cores, and zirconia crowns, followed by thermocycling. Fracture resistance was measured using a Universal Testing Machine; failure modes were assessed visually, by stereomicroscopy, and by SEM. Data were analyzed using one-way ANOVA with post hoc Tukey's test (p < 0.05). Results: Mean fracture resistance was highest in Group B (49.03 ± 22.90 N), followed by Group C (42.43 ± 21.11 N) and Group A (40.08 ± 11.32 N), with significant differences among all groups (p < 0.05–0.001). Failure mode analysis showed significant differences in fractures below the bone level and vertical root fractures across groups (p < 0.05). Conclusion: Ferrule configuration significantly affects fracture resistance of post- and core-treated premolars. A buccally dominant ferrule design (2 mm buccal, 1 mm lingual) provided greater fracture resistance than the conventional circumferential and lingually dominant configurations, suggesting a biomechanical advantage relevant to restorative decision-making in teeth with asymmetric coronal structure loss.

International Journal of Drug Delivery TechnologyVol. 16(88s)
Tatyasaheb Kore Dental College and Research Centre (IN), Bharati Vidyapeeth (Deemed to be University) (IN)
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon