Development and validation of parallel prediction models for extubation failure and 30-day mortality in patients with acute respiratory distress syndrome complicated by sepsis

Acute Respiratory Distress Syndrome (ARDS) and sepsis are critical conditions with high mortality rates. Predicting extubation failure and 30-day mortality in patients with ARDS complicated by sepsis remains challenging due to overlapping pathophysiology and dynamic clinical variables. This study aimed to develop and validate parallel prediction models for extubation failure and 30-day mortality. We extracted 934 ventilated adults with ARDS and sepsis from MIMIC-IV (2017–2019). Feature selection used LassoCV, XGBoost-RFECV, and SVM-RFECV; their intersection defined endpoint-specific features. Five models (Logistic Regression, AdaBoost, Gradient Boosting Decision Tree [GBDT], Multilayer Perceptron [MLP], and Support Vector Classification [SVC]) were developed. SMOTE and grid search were restricted to the training set, and performance was evaluated in one held-out test set with bootstrap confidence intervals. Metrics included AUC, Brier score, F1 score, and graphical calibration. Lactate and body temperature were the only predictors common to the two endpoint-specific feature sets. For extubation failure, the GBDT AUC was 0.985 in training and 0.873 in the held-out test set; the test-set AUCs for Logistic Regression and SVC were 0.887 and 0.870, respectively. For 30-day mortality, the AdaBoost AUC was 0.863 in training and 0.792 in the test set. These estimates reflect internal evaluation using a single train–test split. The two independently developed models showed preliminary internal discrimination for extubation failure and 30-day mortality. Their combined clinical value was not assessed. External validation and clinical-impact evaluation are needed before either model can be recommended for clinical use.

Authors

Institutions

Publication Details

Journal
BMC Pulmonary Medicine
Published
2026-11-14
DOI
https://doi.org/10.1186/s12890-026-04974-w
Primary Topic
Sepsis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development and validation of parallel prediction models for extubation failure and 30-day mortality in patients with acute respiratory distress syndrome complicated by sepsis

Kai Liu, Di Wang, Hong Sun, Xin Wang et al.
BMC Pulmonary Medicine
Sepsis Diagnosis and Treatment
article

Development and validation of parallel prediction models for extubation failure and 30-day mortality in patients with acute respiratory distress syndrome complicated by sepsis

Kai Liu, Di Wang, Hong Sun, Xin Wang, Qun Liang
article en

Abstract

Acute Respiratory Distress Syndrome (ARDS) and sepsis are critical conditions with high mortality rates. Predicting extubation failure and 30-day mortality in patients with ARDS complicated by sepsis remains challenging due to overlapping pathophysiology and dynamic clinical variables. This study aimed to develop and validate parallel prediction models for extubation failure and 30-day mortality. We extracted 934 ventilated adults with ARDS and sepsis from MIMIC-IV (2017–2019). Feature selection used LassoCV, XGBoost-RFECV, and SVM-RFECV; their intersection defined endpoint-specific features. Five models (Logistic Regression, AdaBoost, Gradient Boosting Decision Tree [GBDT], Multilayer Perceptron [MLP], and Support Vector Classification [SVC]) were developed. SMOTE and grid search were restricted to the training set, and performance was evaluated in one held-out test set with bootstrap confidence intervals. Metrics included AUC, Brier score, F1 score, and graphical calibration. Lactate and body temperature were the only predictors common to the two endpoint-specific feature sets. For extubation failure, the GBDT AUC was 0.985 in training and 0.873 in the held-out test set; the test-set AUCs for Logistic Regression and SVC were 0.887 and 0.870, respectively. For 30-day mortality, the AdaBoost AUC was 0.863 in training and 0.792 in the test set. These estimates reflect internal evaluation using a single train–test split. The two independently developed models showed preliminary internal discrimination for extubation failure and 30-day mortality. Their combined clinical value was not assessed. External validation and clinical-impact evaluation are needed before either model can be recommended for clinical use.

BMC Pulmonary Medicine
Heilongjiang University of Chinese Medicine (CN), First Affiliated Hospital of Heilongjiang University of Chinese Medicine (CN)
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon