Project Argus: The Watchful Base - The Gd2O3 Base of the Angelica Stack as a Built-in Thermal-Neutron Detector: Efficiency, Readout, Gamma Rejection, Base Compound and Benchmark. A Short Computational Paper

Paper 9 of the Angelica Paper Series, a short computational paper. Gadolinium has the largest thermal-neutron capture cross-section of any stable element, and every Angelica wafer carries an epitaxial Gd₂O₃ base directly on silicon that can be depleted as a diode. This paper asks, with nothing measured, how well that base and silicon detect thermal neutrons. The new element is not the Gd-containing diode itself but the fact that the converter and the detecting Si already share one wafer with GaN electronics. Efficiency: A natural base detects 0.35 % (0.1 µm) to 1.59 % (0.5 µm) of 1.8 Å neutrons. 90 % ¹⁵⁷Gd gives 1.61–6.80 %. Uncertainty is about a factor of two. Readout: A 1 mm² pixel reaches a 3.1 keV threshold at room temperature, and 12.3 keV at 125 °C if the interface is inverted. Gamma rejection: A thin depletion layer plus a 26–31 keV window gives a gamma intrinsic efficiency of 7×10⁻⁶ to 1.1×10⁻⁴, which is 7–109× the ³He-replacement criterion. Paired pixels, with the base etched away under half of them, subtract the gamma background. Base: Only Gd sees neutrons. Enriched Gd₂O₃ is 4.3× better, and no Alchemy mixture does better. Soft errors: 99 % of the charge that capture electrons leave in the GaN layers is below 1.4 fC, so the GaN devices above should be unaffected. Argus is a built-in neutron eye, not a ³He replacement. The record contains the paper in English, Traditional Chinese and Japanese, a primer in all three languages, and the full code and sources. Licence: text and figures CC BY 4.0; code Apache-2.0. Defensive publication: disclosed as prior art, free for anyone to use and not to be patented by others. Keywords: thermal neutron detection; gadolinium; Gd2O3; Gd-157; conversion electrons; silicon pixel detector; gamma rejection; He-3 replacement; neutron imaging; soft errors; GaN-on-Si; Angelica Paper Series

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-14
DOI
https://doi.org/10.5281/zenodo.24221116
Primary Topic
Radiation Detection and Scintillator Technologies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Project Argus: The Watchful Base - The Gd2O3 Base of the Angelica Stack as a Built-in Thermal-Neutron Detector: Efficiency, Readout, Gamma Rejection, Base Compound and Benchmark. A Short Computational Paper

Tung Ning Liu
Zenodo (CERN European Organization for Nuclear Research)
Radiation Detection and Scintillator Technologies
preprint

Project Argus: The Watchful Base - The Gd2O3 Base of the Angelica Stack as a Built-in Thermal-Neutron Detector: Efficiency, Readout, Gamma Rejection, Base Compound and Benchmark. A Short Computational Paper

Tung Ning Liu
preprint en

Abstract

Paper 9 of the Angelica Paper Series, a short computational paper. Gadolinium has the largest thermal-neutron capture cross-section of any stable element, and every Angelica wafer carries an epitaxial Gd₂O₃ base directly on silicon that can be depleted as a diode. This paper asks, with nothing measured, how well that base and silicon detect thermal neutrons. The new element is not the Gd-containing diode itself but the fact that the converter and the detecting Si already share one wafer with GaN electronics. Efficiency: A natural base detects 0.35 % (0.1 µm) to 1.59 % (0.5 µm) of 1.8 Å neutrons. 90 % ¹⁵⁷Gd gives 1.61–6.80 %. Uncertainty is about a factor of two. Readout: A 1 mm² pixel reaches a 3.1 keV threshold at room temperature, and 12.3 keV at 125 °C if the interface is inverted. Gamma rejection: A thin depletion layer plus a 26–31 keV window gives a gamma intrinsic efficiency of 7×10⁻⁶ to 1.1×10⁻⁴, which is 7–109× the ³He-replacement criterion. Paired pixels, with the base etched away under half of them, subtract the gamma background. Base: Only Gd sees neutrons. Enriched Gd₂O₃ is 4.3× better, and no Alchemy mixture does better. Soft errors: 99 % of the charge that capture electrons leave in the GaN layers is below 1.4 fC, so the GaN devices above should be unaffected. Argus is a built-in neutron eye, not a ³He replacement. The record contains the paper in English, Traditional Chinese and Japanese, a primer in all three languages, and the full code and sources. Licence: text and figures CC BY 4.0; code Apache-2.0. Defensive publication: disclosed as prior art, free for anyone to use and not to be patented by others. Keywords: thermal neutron detection; gadolinium; Gd2O3; Gd-157; conversion electrons; silicon pixel detector; gamma rejection; He-3 replacement; neutron imaging; soft errors; GaN-on-Si; Angelica Paper Series

Zenodo (CERN European Organization for Nuclear Research)
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.