Emerging Role of Raman Spectroscopy and Near-Infrared Technology in Non-Destructive Pharmaceutical Quality Testing: A Review of Calibration Transfer, Method Robustness and Validation Across Dosage Forms

Conventional pharmaceutical quality control relies largely on destructive, solvent-intensive and time-consuming methods such as HPLC assay, dissolution testing, Karl Fischer titration and wet-chemical identification. These methods are accurate and well established, but they consume samples, generate waste, and give results only after the batch has already been manufactured. Near-infrared (NIR) and Raman spectroscopy are vibrational techniques that need little or no sample preparation, can measure through packaging or in-line, and provide chemical and physical information within seconds. Both techniques are central to Process Analytical Technology (PAT), real-time release testing (RTRT) and continuous manufacturing. Despite this, their routine industrial adoption is limited by three recurring problems: transfer of calibration models between instruments, sites and batches; robustness of multivariate methods against physical and environmental variation; and the absence of a single harmonised approach to validating spectroscopic methods across tablets, capsules, powders, liquids, semi-solids and parenteral products. This review compares destructive and non-destructive analytical approaches, summarises the principles, instrumentation and chemometrics of NIR and Raman methods, surveys their applications by dosage form, and critically examines calibration transfer algorithms, robustness testing and validation under ICH Q2 (R2) and Q14, USP <1119>/<1120> and the European Pharmacopoeia. Research gaps and future directions, including lifecycle-based model maintenance, are discussed.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-14
DOI
https://doi.org/10.5281/zenodo.24217785
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Emerging Role of Raman Spectroscopy and Near-Infrared Technology in Non-Destructive Pharmaceutical Quality Testing: A Review of Calibration Transfer, Method Robustness and Validation Across Dosage Forms

Pranjal Dinesh Ambade, Radhika Pradip Sahare, Pranjali Vinod Farkunde, Mayuri Dhanraj Dhurve et al.
Zenodo (CERN European Organization for Nuclear Research)
Spectroscopy and Chemometric Analyses
article

Emerging Role of Raman Spectroscopy and Near-Infrared Technology in Non-Destructive Pharmaceutical Quality Testing: A Review of Calibration Transfer, Method Robustness and Validation Across Dosage Forms

Pranjal Dinesh Ambade, Radhika Pradip Sahare, Pranjali Vinod Farkunde, Mayuri Dhanraj Dhurve, Aditi Sunil Raut
article en

Abstract

Conventional pharmaceutical quality control relies largely on destructive, solvent-intensive and time-consuming methods such as HPLC assay, dissolution testing, Karl Fischer titration and wet-chemical identification. These methods are accurate and well established, but they consume samples, generate waste, and give results only after the batch has already been manufactured. Near-infrared (NIR) and Raman spectroscopy are vibrational techniques that need little or no sample preparation, can measure through packaging or in-line, and provide chemical and physical information within seconds. Both techniques are central to Process Analytical Technology (PAT), real-time release testing (RTRT) and continuous manufacturing. Despite this, their routine industrial adoption is limited by three recurring problems: transfer of calibration models between instruments, sites and batches; robustness of multivariate methods against physical and environmental variation; and the absence of a single harmonised approach to validating spectroscopic methods across tablets, capsules, powders, liquids, semi-solids and parenteral products. This review compares destructive and non-destructive analytical approaches, summarises the principles, instrumentation and chemometrics of NIR and Raman methods, surveys their applications by dosage form, and critically examines calibration transfer algorithms, robustness testing and validation under ICH Q2 (R2) and Q14, USP <1119>/<1120> and the European Pharmacopoeia. Research gaps and future directions, including lifecycle-based model maintenance, are discussed.

Zenodo (CERN European Organization for Nuclear Research)
Datta Meghe Institute of Higher Education and Research (IN)
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon