Quantification-Guided Acceptance beyond Baseline Separation for Rapid Closed-Loop Gas Chromatography

Abstract Chromatographic method development typically resolves peaks before calibration and quantification. Here, we introduce a quantification-guided closed-loop strategy that selects methods by experimentally demonstrated calibration performance rather than baseline separation. The workflow combines automated gas-chromatographic experimentation, simultaneous multicomponent exponentially modified Gaussian fitting, external- or internal-standard calibration, and constrained large-language-model recommendations. The model proposes bounded parameter changes, while deterministic software enforces operating limits, generates executable conditions, and applies predefined acceptance criteria. Across one external-standard and three internal-standard systems containing two to four analytes, selected methods achieved run times of 2.2−2.7 min and minimum analyte-specific R2 values of 0.994−0.999, respectively. In the five-component system, calibration slope RSDs were below 0.30% across five independently prepared calibration series. All 12 analyte-level predictions in three validation mixtures had absolute relative errors below 9%, and mean spike recoveries were 97.61−103.90%. These results indicate that baseline separation need not be universal when overlapping components remain identifiable, and quantitative performance is experimentally verified. More broadly, quantitative validity as a feedback signal moves chromatography from a passive measurement endpoint toward a bounded autonomous process for self-driving laboratories and compositionally bounded high-throughput workflows.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-11-14
DOI
https://doi.org/10.1021/acs.analchem.6c05466
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Quantification-Guided Acceptance beyond Baseline Separation for Rapid Closed-Loop Gas Chromatography

Linjiang Chen, Xiaobo Li, Jun Jiang, Zhou Shi et al.
Analytical Chemistry
Analytical Chemistry and Chromatography
article

Quantification-Guided Acceptance beyond Baseline Separation for Rapid Closed-Loop Gas Chromatography

Linjiang Chen, Xiaobo Li, Jun Jiang, Zhou Shi, Zikai Xie, Luyao Ge
article en

Abstract

Abstract Chromatographic method development typically resolves peaks before calibration and quantification. Here, we introduce a quantification-guided closed-loop strategy that selects methods by experimentally demonstrated calibration performance rather than baseline separation. The workflow combines automated gas-chromatographic experimentation, simultaneous multicomponent exponentially modified Gaussian fitting, external- or internal-standard calibration, and constrained large-language-model recommendations. The model proposes bounded parameter changes, while deterministic software enforces operating limits, generates executable conditions, and applies predefined acceptance criteria. Across one external-standard and three internal-standard systems containing two to four analytes, selected methods achieved run times of 2.2−2.7 min and minimum analyte-specific R2 values of 0.994−0.999, respectively. In the five-component system, calibration slope RSDs were below 0.30% across five independently prepared calibration series. All 12 analyte-level predictions in three validation mixtures had absolute relative errors below 9%, and mean spike recoveries were 97.61−103.90%. These results indicate that baseline separation need not be universal when overlapping components remain identifiable, and quantitative performance is experimentally verified. More broadly, quantitative validity as a feedback signal moves chromatography from a passive measurement endpoint toward a bounded autonomous process for self-driving laboratories and compositionally bounded high-throughput workflows.

Analytical Chemistry
University of Science and Technology of China (CN)
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon