Design and comparison of custom cranial prostheses made of titanium and polyether ether ketone using the finite element method

Abstract Cranioplasty is a surgical procedure for reconstructing cranial defects. This study compared the biomechanical performance of patient-specific cranial implants made of Ti6Al4V and PEEK using finite element analysis. A 3D model was reconstructed from CT data of a 19-year-old male with a right parietal defect. Static loads (50–400 N) were applied at three anatomical regions. PEEK implants exhibited higher von Mises stresses than titanium implants, while transferring more load to the surrounding bone. Stress concentration occurred in Region 3 under loads >200 N. Titanium provided greater protection to bone at the cost of stress shielding, whereas PEEK offered more physiological load sharing. Results highlight the importance of material selection based on defect location and expected loading conditions.

Authors

Institutions

Publication Details

Journal
Journal of Materials Science Materials in Medicine
Published
2026-11-14
DOI
https://doi.org/10.1007/s10856-026-07128-w
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design and comparison of custom cranial prostheses made of titanium and polyether ether ketone using the finite element method

Cyrus Ahmadi Toussi, Reza Ghasemi
Journal of Materials Science Materials in Medicine
Bone Tissue Engineering Materials
article

Design and comparison of custom cranial prostheses made of titanium and polyether ether ketone using the finite element method

Cyrus Ahmadi Toussi, Reza Ghasemi
article en

Abstract

Abstract Cranioplasty is a surgical procedure for reconstructing cranial defects. This study compared the biomechanical performance of patient-specific cranial implants made of Ti6Al4V and PEEK using finite element analysis. A 3D model was reconstructed from CT data of a 19-year-old male with a right parietal defect. Static loads (50–400 N) were applied at three anatomical regions. PEEK implants exhibited higher von Mises stresses than titanium implants, while transferring more load to the surrounding bone. Stress concentration occurred in Region 3 under loads >200 N. Titanium provided greater protection to bone at the cost of stress shielding, whereas PEEK offered more physiological load sharing. Results highlight the importance of material selection based on defect location and expected loading conditions.

Journal of Materials Science Materials in Medicine
Tabaran Institute of Higher Education (IR)
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon