SMART GRID-BASED SOLUTIONS TO PROTECTION SYSTEM CHALLENGES ARISING FROM PV INTEGRATION IN POWER NETWORKS

The presence of photovoltaic (PV) in the distribution network leads to inefficient protection devices that cannot detect the fault correctly because it changes the radial system to a bidirectional system; therefore, the need for an active protection scheme is necessary. This paper suggests an adaptive protection scheme that updates its settings automatically based on a communication link between PV units and the protection relays. The proposed scheme used ETAP software to simulate an 11 kV radial system with PV installation. The results show an important improvement where the scheme is able to detect and isolate the fault within 200 milliseconds. The miscoordination decreased by 35 % in comparison to conventional protection schemes, in addition to reliability enhancement without complex computation

Authors

Publication Details

Journal
Kufa Journal of Engineering
Published
2026-11-14
DOI
https://doi.org/10.30572/2018/kje/170415
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

SMART GRID-BASED SOLUTIONS TO PROTECTION SYSTEM CHALLENGES ARISING FROM PV INTEGRATION IN POWER NETWORKS

Zaid Alhadrawi, Jinan Charafeddine, Ameer Aqeel Kamoona, Wafaa Shakir et al.
Kufa Journal of Engineering
Power Systems Fault Detection
article

SMART GRID-BASED SOLUTIONS TO PROTECTION SYSTEM CHALLENGES ARISING FROM PV INTEGRATION IN POWER NETWORKS

Zaid Alhadrawi, Jinan Charafeddine, Ameer Aqeel Kamoona, Wafaa Shakir, Ali Salah AlKhafaji
article en

Abstract

The presence of photovoltaic (PV) in the distribution network leads to inefficient protection devices that cannot detect the fault correctly because it changes the radial system to a bidirectional system; therefore, the need for an active protection scheme is necessary. This paper suggests an adaptive protection scheme that updates its settings automatically based on a communication link between PV units and the protection relays. The proposed scheme used ETAP software to simulate an 11 kV radial system with PV installation. The results show an important improvement where the scheme is able to detect and isolate the fault within 200 milliseconds. The miscoordination decreased by 35 % in comparison to conventional protection schemes, in addition to reliability enhancement without complex computation

Kufa Journal of EngineeringVol. 17(4)
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon