Depth of Shower Maximum at the Pierre Auger Observatory: Elongation Rate and the Proton-Iron Separation
This paper computes a shower-development budget for the Pierre Auger Observatory in Mendoza Province, Argentina, using published observations as inputs and standard relations stated in full. The principal computed quantities are: D10 g cm2 per decade = 56; elongation per efold g cm2 = 24.32; energy eV 1e+18, xmax proton g cm2 697, xmax iron g cm2 597, separation g cm2 100; energy eV 3.16e+18, xmax proton g cm2 725, xmax iron g cm2 625, separation g cm2 100; energy eV 1e+19, xmax proton g cm2 753, xmax iron g cm2 653, separation g cm2 100; energy eV 3.16e+19, xmax proton g cm2 781, xmax iron g cm2 681, separation g cm2 100. Each value is derived in the deposited code from the stated inputs, so the budget can be re-run with alternative published values. The results place this measurement quantitatively alongside other observatories and energy ranges treated with the same relations, and the discussion identifies which input dominates the uncertainty of each headline number. Computed from stated assumptions and published data, not a new measurement.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-14
- DOI
- https://doi.org/10.5281/zenodo.24229187
- Primary Topic
- Astrophysics and Cosmic Phenomena
- Type
- article
- Field-Weighted Citation Impact
- 0.00