Stability analysis of ultra-high arch dams under temperature-stress coupling and cumulative temperature damage
In the high-altitude regions of southwestern China, large diurnal and annual temperature fluctuations impose substantial thermal loads on ultra-high arch dams. Given their marked sensitivity to thermal variations, these structures face considerable threats to their safety and stability. To investigate the coupling effect between the temperature and stress fields of the dam body under high‑altitude and large temperature difference conditions, and to assess the influence of cumulative thermal damage on the structural response of the arch dam, this study takes a 217 m high asymmetric double curvature concrete arch dam as the research object. A thermo‑mechanical coupled numerical model is established using the ANSYS finite element method, incorporating self‑weight, hydrostatic pressure, silt pressure, and thermal loads. The displacement and stress field distributions of the dam under two operating conditions—sudden temperature rise and sudden temperature drop at normal storage level—are comparatively analyzed. The results indicate that the total displacement on the upstream face exhibits a symmetrical arc‑shaped distribution centered at the crown of the dam crest. It slightly increases under cooling and slightly decreases under warming, with magnitudes remaining within the normal elastic range. A temperature decrease causes the dam crest to deflect downstream, whereas a temperature increase causes it to deflect upstream. In the direction perpendicular to the river channel, significant torsional deformation is observed due to thermal regulation: clockwise torsion under cooling and counterclockwise torsion under warming, with consistent deformation patterns on both upstream and downstream faces. Under the cooling condition, compressive stresses dominate in the dam body, with tensile stress concentration occurring at the upstream arch abutments. Under the warming condition, the upstream stress distribution is more uniform, while tensile stress in the downstream restraint zone increases. Finally, the stability of the dam foundation and the arch abutments on both banks is analyzed using the non‑uniformity coefficient. Thermal loads significantly alter the deformation patterns and stress distributions of the arch dam through thermal expansion and contraction effects. These findings can provide a theoretical basis and model reference for temperature control design and safety evaluation of high arch dams.
Authors
- Yihan Yu
- Zhenchao Wang
- Xijun Zhang
- Chaojie Wang
- Jin Qian
Institutions
- North China University of Water Resources and Electric Power (CN)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-14
- DOI
- https://doi.org/10.1038/s41598-026-78502-5
- Primary Topic
- Dam Engineering and Safety
- Type
- article
- Field-Weighted Citation Impact
- 0.00