Bayesian Reliability Modeling and Maintenance Recommendations for Cryogenic Hydrogen Pump Cold Ends

Downtime and reliability issues are a significant challenge for hydrogen fueling stations. A leading cause of equipment-related downtime at liquid hydrogen stations is failure of cryogenic reciprocating pump cold ends. Reliability modeling can inform component maintenance, design, and operation. We define a Bayesian updating methodology for cryogenic pump cold end reliability modeling to produce time to failure distributions and recommend preventative maintenance times for each failure mode while addressing sparse failure data and enabling model updating as new data becomes available. We demonstrate the methodology for the four most frequently occurring cold end failure modes. Results show how to adapt understanding of equipment performance as new data are gathered, which enables more adaptive and nuanced maintenance decision making. We provide maintenance recommendations that show preventative maintenance scheduling should vary depending on the failure mode. The methodology can be applied to additional components to improve the reliability of hydrogen infrastructure.

Authors

Institutions

Publication Details

Journal
International Journal of Hydrogen Energy
Published
2026-11-14
DOI
https://doi.org/10.1016/j.ijhydene.2026.158641
Primary Topic
Reliability and Maintenance Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Bayesian Reliability Modeling and Maintenance Recommendations for Cryogenic Hydrogen Pump Cold Ends

Katrina M. Groth, Cristian Schaad, Lauren M. Reising, Adrian Maker
International Journal of Hydrogen Energy
Reliability and Maintenance Optimization
article

Bayesian Reliability Modeling and Maintenance Recommendations for Cryogenic Hydrogen Pump Cold Ends

Katrina M. Groth, Cristian Schaad, Lauren M. Reising, Adrian Maker
article en

Abstract

Downtime and reliability issues are a significant challenge for hydrogen fueling stations. A leading cause of equipment-related downtime at liquid hydrogen stations is failure of cryogenic reciprocating pump cold ends. Reliability modeling can inform component maintenance, design, and operation. We define a Bayesian updating methodology for cryogenic pump cold end reliability modeling to produce time to failure distributions and recommend preventative maintenance times for each failure mode while addressing sparse failure data and enabling model updating as new data becomes available. We demonstrate the methodology for the four most frequently occurring cold end failure modes. Results show how to adapt understanding of equipment performance as new data are gathered, which enables more adaptive and nuanced maintenance decision making. We provide maintenance recommendations that show preventative maintenance scheduling should vary depending on the failure mode. The methodology can be applied to additional components to improve the reliability of hydrogen infrastructure.

International Journal of Hydrogen EnergyVol. 293
University of Maryland, College Park (US)
University of Maryland
Reliability and Maintenance Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon