EFFECT OF AIR MASS FLOW RATE ON THE PERFORMANCE OF AN EARTH AIR HEAT EXCHANGER USED IN COOLING THE ELECTRIC MOTOR OF AN OIL PUMP: A NUMERICAL INVESTIGATION

Elevated temperatures in electric motors significantly contribute to diminished efficiency and a reduced lifespan. An EAHE can be utilized as an efficient cooling method to lessen this issue. This study designed a theoretical model of a 3-phase, squirrel-cage induction motor using ANSYS 2024/FLUENT software. The motor was connected to an underground pipe 4 m deep. This research numerically investigated several design parameters, including the effect of air mass flow rate, pipe diameter, outlet condition, and required cooling load. The study utilized 90 m of PVC (polyvinyl chloride) earth-air heat exchanger (EAHE) pipes with an inlet temperature of 50°C, based on the climatic conditions of Nasiriyah, southern Iraq. The results showed that raising the air mass flow rate reduces the electric motor temperature. The observed reduction in the maximum motor temperature was approximately 11.00%, 11.51%, and 11.85% for pipe diameters of 6, 4, and 3 in, respectively. This shows that the smaller the diameter, the greater the ratio of reduction, and this results in increased system efficiency. An EAHE is effective in its use, bringing the electric motor temperature down, which leads its performance to an increase in efficiency and increases its life

Authors

Publication Details

Journal
Kufa Journal of Engineering
Published
2026-11-14
DOI
https://doi.org/10.30572/2018/kje/170433
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

EFFECT OF AIR MASS FLOW RATE ON THE PERFORMANCE OF AN EARTH AIR HEAT EXCHANGER USED IN COOLING THE ELECTRIC MOTOR OF AN OIL PUMP: A NUMERICAL INVESTIGATION

Rafid M. Hannun, Baraa A. Gaber
Kufa Journal of Engineering
Geothermal Energy Systems and Applications
article

EFFECT OF AIR MASS FLOW RATE ON THE PERFORMANCE OF AN EARTH AIR HEAT EXCHANGER USED IN COOLING THE ELECTRIC MOTOR OF AN OIL PUMP: A NUMERICAL INVESTIGATION

Rafid M. Hannun, Baraa A. Gaber
article en

Abstract

Elevated temperatures in electric motors significantly contribute to diminished efficiency and a reduced lifespan. An EAHE can be utilized as an efficient cooling method to lessen this issue. This study designed a theoretical model of a 3-phase, squirrel-cage induction motor using ANSYS 2024/FLUENT software. The motor was connected to an underground pipe 4 m deep. This research numerically investigated several design parameters, including the effect of air mass flow rate, pipe diameter, outlet condition, and required cooling load. The study utilized 90 m of PVC (polyvinyl chloride) earth-air heat exchanger (EAHE) pipes with an inlet temperature of 50°C, based on the climatic conditions of Nasiriyah, southern Iraq. The results showed that raising the air mass flow rate reduces the electric motor temperature. The observed reduction in the maximum motor temperature was approximately 11.00%, 11.51%, and 11.85% for pipe diameters of 6, 4, and 3 in, respectively. This shows that the smaller the diameter, the greater the ratio of reduction, and this results in increased system efficiency. An EAHE is effective in its use, bringing the electric motor temperature down, which leads its performance to an increase in efficiency and increases its life

Kufa Journal of EngineeringVol. 17(4)
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon