Mantle Thermal Budget: Secular Cooling Rate from the Heat-Flow Balance

This paper computes the secular cooling rate of the mantle from the Preliminary Reference Earth Model and related published values. The approach is the balance between the 47 terawatts leaving the surface and the roughly 20 terawatts supplied by radiogenic heating and core heat flow, converted into a cooling rate through the mantle's heat capacity; the specific heat used is an adopted input and is stated as such in the Methods. Headline results are: secular_cooling_power_TW = 17; cooling_rate_K_per_Gyr = 108.4; mantle_heat_capacity_J_K = 4.95e+27. Every number quoted in the text is produced by the deposited compute.py script, which integrates a tabulated anchor representation of the reference density profile in 4000 shells and writes all outputs to results.json. Where a quantity is not tabulated in the reference model, the adopted value and its published range are stated plainly in the Methods, and the sensitivity of the headline result to that choice is discussed. The results are compared with the published values they are meant to check, and differences are reported at full size rather than rounded away. The calculation is a reference-model budget, not a new measurement: its value lies in showing whether the standard layer-by-layer account of the Earth's interior is internally consistent on this quantity, and in identifying which future observation would most improve it.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-14
DOI
https://doi.org/10.5281/zenodo.24216266
Primary Topic
High-pressure geophysics and materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Mantle Thermal Budget: Secular Cooling Rate from the Heat-Flow Balance

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
High-pressure geophysics and materials
article

Mantle Thermal Budget: Secular Cooling Rate from the Heat-Flow Balance

William Alexander Aldred
article en

Abstract

This paper computes the secular cooling rate of the mantle from the Preliminary Reference Earth Model and related published values. The approach is the balance between the 47 terawatts leaving the surface and the roughly 20 terawatts supplied by radiogenic heating and core heat flow, converted into a cooling rate through the mantle's heat capacity; the specific heat used is an adopted input and is stated as such in the Methods. Headline results are: secular_cooling_power_TW = 17; cooling_rate_K_per_Gyr = 108.4; mantle_heat_capacity_J_K = 4.95e+27. Every number quoted in the text is produced by the deposited compute.py script, which integrates a tabulated anchor representation of the reference density profile in 4000 shells and writes all outputs to results.json. Where a quantity is not tabulated in the reference model, the adopted value and its published range are stated plainly in the Methods, and the sensitivity of the headline result to that choice is discussed. The results are compared with the published values they are meant to check, and differences are reported at full size rather than rounded away. The calculation is a reference-model budget, not a new measurement: its value lies in showing whether the standard layer-by-layer account of the Earth's interior is internally consistent on this quantity, and in identifying which future observation would most improve it.

Zenodo (CERN European Organization for Nuclear Research)
High-pressure geophysics and materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon