A Practical Approach to Comprehensive Performance Evaluation, Heat Rate Gap Diagnostics and Ai-Based Real-Time Optimization of Coal-Fired Power Plants
Accurate measurement of boiler efficiency, turbine heat rate (THR), gross heat rate (GHR) and heat rate deviations are fundamental to assessing the true performance of a coal-fired generating unit during Performance Guarantee (PG) test and routine O&M phase. Small errors in coal flow, coal calorific value, steam flow, enthalpy, generator output, flue-gas measurements and correction factors can produce significant errors in calculated heat rate. This paper presents a practical methodology based primarily on ASME Performance Test Codes (PTCs), with emphasis on PTC 4 for fuel fired steam generators, PTC 6 for steam turbines, PTC 46 for overall plant performance and PTC 19.1 for test uncertainty. This paper emphasizes direct and indirect measurement methods, OEM correction curves, heat-rate gap analysis, repeatability, uncertainty, test preparation, coal sampling, practical do's and don'ts and application of AI.
Authors
- Sunil Kumar Gupta
- M Senthil
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-14
- DOI
- https://doi.org/10.5281/zenodo.24213632
- Primary Topic
- Advanced Power Generation Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00