Hemodynamic and respiratory effects of non-invasive ventilation modalities in very preterm infants: a randomized crossover trial

Non-invasive ventilation (NIV) minimizes lung injury in preterm infants. We compared the short-term hemodynamic and respiratory effects of different NIV modalities. Infants <32 weeks’ gestation or birthweight <1500 g on nasal continuous positive airway pressure (NCPAP) were randomized, in a two-sequence crossover design to 2 h each of non-synchronized NIPPV (NS-NIPPV) and neurally synchronized NIPPV (S-NIPPV). Ventricular output and function were assessed by echocardiography, with diaphragm activity and lung aeration evaluated. Linear mixed-effects models were used for analysis. No significant differences were observed in right (RV) or left ventricular (LV) output across modes. RV output tended to be higher during S-NIPPV than NS-NIPPV (mean difference 24 mL/kg/min [95% CI; −3 to 51]; p = 0.08). NS-NIPPV was associated with a greater magnitude of LV peak global longitudinal strain (−2.54 [95% CI; −4.61 to -0.48]; p = 0.02) and strain rate (−0.45 [95% CI; −0.78 to −0.11]; p = 0.008) compared to NCPAP. S-NIPPV reduced peak Edi (7.2 ± 5.1 µV vs NCPAP 10.0 ± 6.8 µV ; p < 0.01 ) . Both NIPPV modes improved lung ultrasound score ( p < 0.001). S-NIPPV showed a non-significant trend toward higher RV output and significantly reduced diaphragm activity compared with NS-NIPPV; both NIPPV modes improved lung aeration relative to NCPAP. Thai Clinical Trials Registry. Registration number TCTR20240804002. Web link: https://www.thaiclinicaltrials.org/show/TCTR20240804002 . In clinically stable very preterm infants, short-term exposure to NCPAP, NS-NIPPV, and S-NIPPV preserved biventricular output and myocardial performance, addressing concerns regarding hemodynamic compromise with higher airway pressures. S-NIPPV was associated with a significant reduction in diaphragmatic workload (peak Edi) and a non-significant trend toward higher RVO, without evidence of adverse cardiac effects; lung aeration improved with both NIPPV modes relative to NCPAP. These exploratory findings generate the hypothesis that the observed benefits are driven by effective pressure delivery rather than synchronization alone, offering mechanistic insight to refine NIV optimization in contemporary neonatal care.

Authors

Institutions

Publication Details

Journal
Pediatric Research
Published
2026-11-14
DOI
https://doi.org/10.1038/s41390-026-05593-1
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Hemodynamic and respiratory effects of non-invasive ventilation modalities in very preterm infants: a randomized crossover trial

Punnanee Wutthigate, Ratchada Kitsommart, Buranee Yangthara, Gabriel Altit et al.
Pediatric Research
Neonatal Respiratory Health Research
article

Hemodynamic and respiratory effects of non-invasive ventilation modalities in very preterm infants: a randomized crossover trial

Punnanee Wutthigate, Ratchada Kitsommart, Buranee Yangthara, Gabriel Altit, Nonthawat Naknin
article en

Abstract

Non-invasive ventilation (NIV) minimizes lung injury in preterm infants. We compared the short-term hemodynamic and respiratory effects of different NIV modalities. Infants <32 weeks’ gestation or birthweight <1500 g on nasal continuous positive airway pressure (NCPAP) were randomized, in a two-sequence crossover design to 2 h each of non-synchronized NIPPV (NS-NIPPV) and neurally synchronized NIPPV (S-NIPPV). Ventricular output and function were assessed by echocardiography, with diaphragm activity and lung aeration evaluated. Linear mixed-effects models were used for analysis. No significant differences were observed in right (RV) or left ventricular (LV) output across modes. RV output tended to be higher during S-NIPPV than NS-NIPPV (mean difference 24 mL/kg/min [95% CI; −3 to 51]; p = 0.08). NS-NIPPV was associated with a greater magnitude of LV peak global longitudinal strain (−2.54 [95% CI; −4.61 to -0.48]; p = 0.02) and strain rate (−0.45 [95% CI; −0.78 to −0.11]; p = 0.008) compared to NCPAP. S-NIPPV reduced peak Edi (7.2 ± 5.1 µV vs NCPAP 10.0 ± 6.8 µV ; p < 0.01 ) . Both NIPPV modes improved lung ultrasound score ( p < 0.001). S-NIPPV showed a non-significant trend toward higher RV output and significantly reduced diaphragm activity compared with NS-NIPPV; both NIPPV modes improved lung aeration relative to NCPAP. Thai Clinical Trials Registry. Registration number TCTR20240804002. Web link: https://www.thaiclinicaltrials.org/show/TCTR20240804002 . In clinically stable very preterm infants, short-term exposure to NCPAP, NS-NIPPV, and S-NIPPV preserved biventricular output and myocardial performance, addressing concerns regarding hemodynamic compromise with higher airway pressures. S-NIPPV was associated with a significant reduction in diaphragmatic workload (peak Edi) and a non-significant trend toward higher RVO, without evidence of adverse cardiac effects; lung aeration improved with both NIPPV modes relative to NCPAP. These exploratory findings generate the hypothesis that the observed benefits are driven by effective pressure delivery rather than synchronization alone, offering mechanistic insight to refine NIV optimization in contemporary neonatal care.

Pediatric Research
Siriraj Hospital (TH), Mahidol University (TH), Montreal Children's Hospital (CA)
Neonatal Respiratory Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon