Depot with Redundant Reverse Turbo-Brayton Cryocoolers

This paper presents a computed design study of a cryogenic propellant depot whose operating principle is redundant reverse turbo-Brayton cryocoolers sized so any single unit can carry the full thermal load. The depot stores 18000 kilograms of liquid oxygen at 90.2 kelvin in a spherical tank of radius 2.5 metres, with a computed heat leak of 0.864 watts, a boiloff rate of 0.3504 kilograms per day, a cryocooler power of 11.2 watts where active cooling is applied, and a transfer-line chilldown cost of 82.738 kilograms. All numbers are computed in the deposited script from stated inputs; nothing is measured. The study is for civilian in-space logistics only. It is a computed study with no targeting or weapon application, and no part of the design is adapted to any such use. The purpose is to show, with auditable arithmetic, whether this operating principle closes its thermal, fluid and power budgets for long-duration storage and transfer.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-14
DOI
https://doi.org/10.5281/zenodo.24218852
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Depot with Redundant Reverse Turbo-Brayton Cryocoolers

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Spacecraft and Cryogenic Technologies
article

Depot with Redundant Reverse Turbo-Brayton Cryocoolers

William Alexander Aldred
article en

Abstract

This paper presents a computed design study of a cryogenic propellant depot whose operating principle is redundant reverse turbo-Brayton cryocoolers sized so any single unit can carry the full thermal load. The depot stores 18000 kilograms of liquid oxygen at 90.2 kelvin in a spherical tank of radius 2.5 metres, with a computed heat leak of 0.864 watts, a boiloff rate of 0.3504 kilograms per day, a cryocooler power of 11.2 watts where active cooling is applied, and a transfer-line chilldown cost of 82.738 kilograms. All numbers are computed in the deposited script from stated inputs; nothing is measured. The study is for civilian in-space logistics only. It is a computed study with no targeting or weapon application, and no part of the design is adapted to any such use. The purpose is to show, with auditable arithmetic, whether this operating principle closes its thermal, fluid and power budgets for long-duration storage and transfer.

Zenodo (CERN European Organization for Nuclear Research)
Spacecraft and Cryogenic Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon