Experimental Assessment of Leakage, Housing Temperature, Vibration and Wear in a Centrifugal-Pump Mechanical Seal under Variable Operating Conditions

Mechanical seals are critical components of centrifugal pumps because they prevent leakage along the rotating shaft while operating under simultaneous hydraulic, thermal and tribological loading. Progressive degradation can result in increased leakage, temperature rise, elevated vibration and eventual pump failure. This paper reports an experimental investigation of a single mechanical seal installed on a laboratory centrifugal pump under variable rotational speed, discharge pressure and flow conditions. A 2.2 kW single-stage centrifugal pump with a 25 mm shaft and a carbon/ceramic mechanical seal was used. Seal leakage, seal-housing temperature, pump vibration, pressure and flow rate were measured at controlled operating conditions spanning 1,500–2,900 rpm and 1.0–3.0 bar (15 conditions × 3 replicates = 45 observations). Seal wear was evaluated through mass measurements and visual examination after a cumulative 100 h operating programme. Leakage rate increased from 0.42 ± 0.01 mL/min at 1,500 rpm and 1.0 bar to 1.70 ± 0.04 mL/min at 2,900 rpm and 3.0 bar. Seal-housing temperature rose correspondingly from 34.0 ± 0.4 °C to 71.0 ± 0.4 °C, while vibration velocity increased from 1.40 ± 0.04 mm/s to 3.30 ± 0.06 mm/s. After 100 h the carbon face lost 12.4 mg. A two-way ANOVA confirmed highly significant main effects of rotational speed and discharge pressure, and a significant speed × pressure interaction, on leakage rate (all p < 0.001). A strong linear association was observed between seal-housing temperature and leakage (R² = 0.966). The results support improved mechanical-seal selection, operating practice and condition-based maintenance strategies, subject to the limitations of a single seal design, clean water as the working fluid and a short laboratory test duration.

Authors

Institutions

Publication Details

Published
2026-11-14
DOI
https://doi.org/10.54117/fa673656
Primary Topic
Tribology and Lubrication Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experimental Assessment of Leakage, Housing Temperature, Vibration and Wear in a Centrifugal-Pump Mechanical Seal under Variable Operating Conditions

Lucky Olatunde ODEJIMI, Olorunleke Aregbe, Emeke Achojakimoni Okotie
Tribology and Lubrication Engineering
article

Experimental Assessment of Leakage, Housing Temperature, Vibration and Wear in a Centrifugal-Pump Mechanical Seal under Variable Operating Conditions

Lucky Olatunde ODEJIMI, Olorunleke Aregbe, Emeke Achojakimoni Okotie
article en

Abstract

Mechanical seals are critical components of centrifugal pumps because they prevent leakage along the rotating shaft while operating under simultaneous hydraulic, thermal and tribological loading. Progressive degradation can result in increased leakage, temperature rise, elevated vibration and eventual pump failure. This paper reports an experimental investigation of a single mechanical seal installed on a laboratory centrifugal pump under variable rotational speed, discharge pressure and flow conditions. A 2.2 kW single-stage centrifugal pump with a 25 mm shaft and a carbon/ceramic mechanical seal was used. Seal leakage, seal-housing temperature, pump vibration, pressure and flow rate were measured at controlled operating conditions spanning 1,500–2,900 rpm and 1.0–3.0 bar (15 conditions × 3 replicates = 45 observations). Seal wear was evaluated through mass measurements and visual examination after a cumulative 100 h operating programme. Leakage rate increased from 0.42 ± 0.01 mL/min at 1,500 rpm and 1.0 bar to 1.70 ± 0.04 mL/min at 2,900 rpm and 3.0 bar. Seal-housing temperature rose correspondingly from 34.0 ± 0.4 °C to 71.0 ± 0.4 °C, while vibration velocity increased from 1.40 ± 0.04 mm/s to 3.30 ± 0.06 mm/s. After 100 h the carbon face lost 12.4 mg. A two-way ANOVA confirmed highly significant main effects of rotational speed and discharge pressure, and a significant speed × pressure interaction, on leakage rate (all p < 0.001). A strong linear association was observed between seal-housing temperature and leakage (R² = 0.966). The results support improved mechanical-seal selection, operating practice and condition-based maintenance strategies, subject to the limitations of a single seal design, clean water as the working fluid and a short laboratory test duration.

Vol. 3(3)
Igbinedion University (NG)
Tribology and Lubrication Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon