Results of Pulmonary Valve Replacement with The INSPIRIS RESILIA Prosthesis: A Systematic Review.

INTRODUCTION: Pulmonary valve replacement is increasingly common in patients with congenital heart disease. The limited durability of conventional bioprostheses has led to the introduction of the INSPIRIS RESILIA valve, initially designed for the aortic position. However, evidence on its performance in the pulmonary position is limited and heterogeneous. METHODS: A systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement in PubMed®, Excerpta Medica dataBASE, Cochrane Library, and ClinicalTrials. Observational studies with patients undergoing pulmonary valve replacement with the INSPIRIS RESILIA bioprosthesis were included. Data on baseline characteristics, transvalvular gradients, mortality, complications, prosthetic insuficiency, and need for reintervention were extracted. This study was registered in the International Prospective Register of Systematic Reviews (CRD420251117859). RESULTS: Three retrospective cohort studies and two retrospective case series were identified that included pediatric and adult populations, mainly with a diagnosis of tetralogy of Fallot. The findings were consistent in showing adequate perioperative safety. Smaller studies showed favorable results. In contrast, larger studies with longer follow-up reported more rapid progression to moderate/severe pulmonary insuficiency and shorter durability of the bioprosthesis. CONCLUSION: INSPIRIS RESILIA may be associated with acceptable short-term outcomes in pulmonary valve replacement, but its medium- and long-term durability may be inferior to that of reference bioprostheses. Medium- and long-term safety remains inconclusive due to limited follow-up, modest sample sizes, heterogeneity in definitions, possible confounding by anatomical substrate, and study limitations.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2026-11-13
DOI
https://doi.org/10.21470/1678-9741-2025-0441
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Results of Pulmonary Valve Replacement with The INSPIRIS RESILIA Prosthesis: A Systematic Review.

Juan de la Parra, Carlos J. Pérez, Leandro Guarin Munoz, William Rios et al.
PubMed
Congenital Heart Disease Studies
article

Results of Pulmonary Valve Replacement with The INSPIRIS RESILIA Prosthesis: A Systematic Review.

Juan de la Parra, Carlos J. Pérez, Leandro Guarin Munoz, William Rios, Diego Penagos-López, Federico Núñez-Ricardo, Guillermo Portilla-Rodríguez, Oscar Sánchez-Colmenares
article en

Abstract

INTRODUCTION: Pulmonary valve replacement is increasingly common in patients with congenital heart disease. The limited durability of conventional bioprostheses has led to the introduction of the INSPIRIS RESILIA valve, initially designed for the aortic position. However, evidence on its performance in the pulmonary position is limited and heterogeneous. METHODS: A systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement in PubMed®, Excerpta Medica dataBASE, Cochrane Library, and ClinicalTrials. Observational studies with patients undergoing pulmonary valve replacement with the INSPIRIS RESILIA bioprosthesis were included. Data on baseline characteristics, transvalvular gradients, mortality, complications, prosthetic insuficiency, and need for reintervention were extracted. This study was registered in the International Prospective Register of Systematic Reviews (CRD420251117859). RESULTS: Three retrospective cohort studies and two retrospective case series were identified that included pediatric and adult populations, mainly with a diagnosis of tetralogy of Fallot. The findings were consistent in showing adequate perioperative safety. Smaller studies showed favorable results. In contrast, larger studies with longer follow-up reported more rapid progression to moderate/severe pulmonary insuficiency and shorter durability of the bioprosthesis. CONCLUSION: INSPIRIS RESILIA may be associated with acceptable short-term outcomes in pulmonary valve replacement, but its medium- and long-term durability may be inferior to that of reference bioprostheses. Medium- and long-term safety remains inconclusive due to limited follow-up, modest sample sizes, heterogeneity in definitions, possible confounding by anatomical substrate, and study limitations.

PubMedVol. 41(4)
Universidad El Bosque (CO), Fundación Cardiovascular de Colombia (CO), Fundación Santa Fe de Bogotá (CO)
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon