Inter-rater reliability, agreement and measurement error of CT-based three-dimensional proximal femoral morphometry in dry cadaveric femora

Abstract Computed tomography (CT)-based three-dimensional (3D) morphometry is widely used to describe the proximal femur, yet the measurement properties of individual parameters are rarely reported. We quantified the inter-rater reliability, agreement and measurement error of ten proximal femoral parameters measured independently by two blinded raters on 3D models of 20 adult dry cadaveric femora. Reliability was quantified with the intraclass correlation coefficient [ICC(2,1)], measurement error with the standard error of measurement (SEM) and minimal detectable change, and agreement and systematic bias with Bland–Altman analysis and paired t-tests. Six linear dimensions and the distal canal diameter (FCD2) showed excellent reliability (ICC 0.936–0.995; SEM 0.32–1.31 mm). The neck-shaft angle showed good reliability (ICC 0.778), and femoral anteversion (FAA; ICC 0.676) and the proximal canal diameter (FCD1; ICC 0.705) moderate reliability. Significant systematic differences between raters occurred for FAA (4.55°), FCD1 (1.13 mm) and FCD2 (0.49 mm), the latter despite excellent reliability. FAA had the largest measurement error (SEM 4.90°; limits of agreement − 9.0° to + 18.2°). These results describe agreement between two raters under one protocol; they do not establish anatomical accuracy, which requires comparison with a reference standard.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-14
DOI
https://doi.org/10.1038/s41598-026-80074-3
Primary Topic
Reliability and Agreement in Measurement
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Inter-rater reliability, agreement and measurement error of CT-based three-dimensional proximal femoral morphometry in dry cadaveric femora

Nur Arfian, Yudha Mathan Sakti, Arif Faisal, Mohammad Imad Awad Ghannam
Scientific Reports
Reliability and Agreement in Measurement
article

Inter-rater reliability, agreement and measurement error of CT-based three-dimensional proximal femoral morphometry in dry cadaveric femora

Nur Arfian, Yudha Mathan Sakti, Arif Faisal, Mohammad Imad Awad Ghannam
article en

Abstract

Abstract Computed tomography (CT)-based three-dimensional (3D) morphometry is widely used to describe the proximal femur, yet the measurement properties of individual parameters are rarely reported. We quantified the inter-rater reliability, agreement and measurement error of ten proximal femoral parameters measured independently by two blinded raters on 3D models of 20 adult dry cadaveric femora. Reliability was quantified with the intraclass correlation coefficient [ICC(2,1)], measurement error with the standard error of measurement (SEM) and minimal detectable change, and agreement and systematic bias with Bland–Altman analysis and paired t-tests. Six linear dimensions and the distal canal diameter (FCD2) showed excellent reliability (ICC 0.936–0.995; SEM 0.32–1.31 mm). The neck-shaft angle showed good reliability (ICC 0.778), and femoral anteversion (FAA; ICC 0.676) and the proximal canal diameter (FCD1; ICC 0.705) moderate reliability. Significant systematic differences between raters occurred for FAA (4.55°), FCD1 (1.13 mm) and FCD2 (0.49 mm), the latter despite excellent reliability. FAA had the largest measurement error (SEM 4.90°; limits of agreement − 9.0° to + 18.2°). These results describe agreement between two raters under one protocol; they do not establish anatomical accuracy, which requires comparison with a reference standard.

Scientific Reports
Universitas Gadjah Mada (ID), Arab American University (PS)
Reliability and Agreement in Measurement
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon