Agreement and Repeatability of a Time-Interval Measurement Prototype for Controlled Horizontal-Displacement Tasks

The development of locally engineered technology for human movement assessment offers an alternative to costly imported instruments. This instrumental method-comparison study evaluated the repeatability of Prototype II, a photocell-based electronic device for measuring time intervals during controlled horizontal-displacement tasks, and its agreement with Newtest Powertimer and Chronojump Boscosystem in indoor and outdoor environments. Repeatability was assessed at 1.5, 6, and 15 s in sessions separated by 24 hours. Agreement was assessed at 2, 5, and 12 s using 35 paired technical repetitions for each interval-by-environment condition, with simultaneous measurements from Prototype II and both comparison systems. Relative reliability was summarized with ICC(2,1), while absolute repeatability was prioritized using CV% and SEM; agreement was summarized with Lin's CCC. ICCs for repeated Prototype II measurements were low or negative under restricted between-trial variance, whereas CV% ranged from 0.49% to 1.92% and SEM from 0.019 to 0.042 s. CCC ranged from 0.94 to 0.99 outdoors, from 0.809 to 0.915 indoors at 2 and 5 s, and from 0.623 to 0.636 at 12 s indoors. These results support repeatable technical performance and substantial agreement in several tested conditions, particularly outdoors, but do not establish practical interchangeability because no a priori acceptable-difference threshold was defined. Prototype II is a promising locally developed timing system that warrants further validation against traceable standards and during real movement tasks.

Authors

Publication Details

Journal
Revista de Ciencias del Ejercicio FOD
Published
2026-11-13
DOI
https://doi.org/10.29105/rce-fod.v21i2.211
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Agreement and Repeatability of a Time-Interval Measurement Prototype for Controlled Horizontal-Displacement Tasks

Ana Ulloa-Sandí, Randall Gutiérrez-Vargas, José Pino‐Ortega, Daniel Rojas‐Valverde
Revista de Ciencias del Ejercicio FOD
Sports Performance and Training
article

Agreement and Repeatability of a Time-Interval Measurement Prototype for Controlled Horizontal-Displacement Tasks

Ana Ulloa-Sandí, Randall Gutiérrez-Vargas, José Pino‐Ortega, Daniel Rojas‐Valverde
article en

Abstract

The development of locally engineered technology for human movement assessment offers an alternative to costly imported instruments. This instrumental method-comparison study evaluated the repeatability of Prototype II, a photocell-based electronic device for measuring time intervals during controlled horizontal-displacement tasks, and its agreement with Newtest Powertimer and Chronojump Boscosystem in indoor and outdoor environments. Repeatability was assessed at 1.5, 6, and 15 s in sessions separated by 24 hours. Agreement was assessed at 2, 5, and 12 s using 35 paired technical repetitions for each interval-by-environment condition, with simultaneous measurements from Prototype II and both comparison systems. Relative reliability was summarized with ICC(2,1), while absolute repeatability was prioritized using CV% and SEM; agreement was summarized with Lin's CCC. ICCs for repeated Prototype II measurements were low or negative under restricted between-trial variance, whereas CV% ranged from 0.49% to 1.92% and SEM from 0.019 to 0.042 s. CCC ranged from 0.94 to 0.99 outdoors, from 0.809 to 0.915 indoors at 2 and 5 s, and from 0.623 to 0.636 at 12 s indoors. These results support repeatable technical performance and substantial agreement in several tested conditions, particularly outdoors, but do not establish practical interchangeability because no a priori acceptable-difference threshold was defined. Prototype II is a promising locally developed timing system that warrants further validation against traceable standards and during real movement tasks.

Revista de Ciencias del Ejercicio FODVol. 21(2)
Sports Performance and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.