Measurement fidelity and external validation of automated breast DCE-MRI segmentation

Automated breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) segmentation could facilitate quantitative tumor measurement, but geometric overlap alone does not establish the fidelity of mask-derived measurements. We developed an enhancement-aware three-dimensional MedNeXt framework with gated skip fusion and boundary supervision and evaluated it in a retrospective multi-cohort design spanning locked internal testing, source-held-out assessment, retrospective external validation, and radiologist review. Measurement fidelity was the primary endpoint. Across 521 paired internal-test and DUKE cases, median errors were 9.7% for tumor volume, 1.8 mm for 3D maximum surface diameter, and 10.2% for operational enhancement-defined volume, with corresponding ICCs of 0.97, 0.80, and 0.97. Median Dice was 0.831 internally and 0.823 in the DUKE source-held-out stratum, and was 0.812 and 0.806 in the BC-MRI-SEG and public BreastDCEDL_AMBL retrospective external-validation cohorts, respectively, using the frozen checkpoint without external-label tuning. No major correction was required for 78 of 80 masks in the blinded two-reader review. In 276 paired response-analysis cases, AUROC was 0.732 with automatic geometry and 0.757 with expert geometry (difference, −0.025; 95% CI, −0.095 to 0.045); discrimination non-inferiority was not demonstrated. These findings support automated segmentation as a starting point for radiologist-supervised retrospective quantitative research within the evaluated cohorts, while distinguishing measurement fidelity from downstream predictive equivalence.

Authors

Institutions

Publication Details

Journal
npj Digital Medicine
Published
2026-11-14
DOI
https://doi.org/10.1038/s41746-026-03446-z
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Measurement fidelity and external validation of automated breast DCE-MRI segmentation

黄元夕, Jian Zheng, Xu Jin, Chunlei Tan et al.
npj Digital Medicine
Medical Image Segmentation Techniques
article

Measurement fidelity and external validation of automated breast DCE-MRI segmentation

黄元夕, Jian Zheng, Xu Jin, Chunlei Tan, Shiyuan Zhang, Li Chen
article en

Abstract

Automated breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) segmentation could facilitate quantitative tumor measurement, but geometric overlap alone does not establish the fidelity of mask-derived measurements. We developed an enhancement-aware three-dimensional MedNeXt framework with gated skip fusion and boundary supervision and evaluated it in a retrospective multi-cohort design spanning locked internal testing, source-held-out assessment, retrospective external validation, and radiologist review. Measurement fidelity was the primary endpoint. Across 521 paired internal-test and DUKE cases, median errors were 9.7% for tumor volume, 1.8 mm for 3D maximum surface diameter, and 10.2% for operational enhancement-defined volume, with corresponding ICCs of 0.97, 0.80, and 0.97. Median Dice was 0.831 internally and 0.823 in the DUKE source-held-out stratum, and was 0.812 and 0.806 in the BC-MRI-SEG and public BreastDCEDL_AMBL retrospective external-validation cohorts, respectively, using the frozen checkpoint without external-label tuning. No major correction was required for 78 of 80 masks in the blinded two-reader review. In 276 paired response-analysis cases, AUROC was 0.732 with automatic geometry and 0.757 with expert geometry (difference, −0.025; 95% CI, −0.095 to 0.045); discrimination non-inferiority was not demonstrated. These findings support automated segmentation as a starting point for radiologist-supervised retrospective quantitative research within the evaluated cohorts, while distinguishing measurement fidelity from downstream predictive equivalence.

npj Digital Medicine
Harbin Medical University (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Third Affiliated Hospital of Harbin Medical University (CN), Cancer Hospital of Chinese Academy of Medical Sciences (CN)
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon