Uncertainty-aware possibilistic load forecasting for smart grid energy conservation

Overview efficient electricity usage management in the presence of deep uncertainty is critical for modern power systems with a high renewable share. We present a fuzzy interval regression framework that represents load observations as triangular fuzzy numbers and estimates α-cut interval forecasts without requiring a full probability distribution. The original eight-hour example is retained only as a transparent calculation: at α = 0.5, the corrected two-weight fit gives an in-sample empirical coverage of 83.3% and a mean interval width of 2.164 MW; these values are descriptive and are neither confidence levels nor predictive validation. To provide out-of-sample evidence, the method was additionally evaluated on the public Taylor half-hourly electricity-demand series for England and Wales (4,032 observations), using the first 3,360 points for estimation and the final 672 points for testing. For the one-step model, the mean absolute error (MAE) was 429.1 MW, the root mean square error (RMSE) was 574.5 MW, and the mean absolute percentage error (MAPE) was 1.45%. The residual-calibrated, time-of-day triangular spreads had an empirical coverage of 91.7% at α = 0.5 and a mean interval width of 1,804.4 MW. An example of demand-response data is given in the form of a 1 MW effort to reduce base load at four defined hours. Assuming a marginal rate of 0.7 tCO₂/MWh, this gross avoided emission would correspond to an estimate of 2.8 tCO₂ not a quantifiable system benefit measurement. The findings favour interpretability and low computational complexity, but practical deployment requires calibrated margins; energy-neutrality or rebound constraints; larger multi-zone trials; and more specific marginal-emission data.

Authors

Publication Details

Journal
Clean Energy Science and Technology
Published
2026-11-13
DOI
https://doi.org/10.18686/cest953
Primary Topic
Energy Load and Power Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Uncertainty-aware possibilistic load forecasting for smart grid energy conservation

Asokan Vasudevan, Nijalingappa Yogeesh, Sulieman Ibraheem Shelash Al-Hawary, P. William et al.
Clean Energy Science and Technology
Energy Load and Power Forecasting
article

Uncertainty-aware possibilistic load forecasting for smart grid energy conservation

Asokan Vasudevan, Nijalingappa Yogeesh, Sulieman Ibraheem Shelash Al-Hawary, P. William, Ali Khwaldeh, Koyel Roy
article en

Abstract

Overview efficient electricity usage management in the presence of deep uncertainty is critical for modern power systems with a high renewable share. We present a fuzzy interval regression framework that represents load observations as triangular fuzzy numbers and estimates α-cut interval forecasts without requiring a full probability distribution. The original eight-hour example is retained only as a transparent calculation: at α = 0.5, the corrected two-weight fit gives an in-sample empirical coverage of 83.3% and a mean interval width of 2.164 MW; these values are descriptive and are neither confidence levels nor predictive validation. To provide out-of-sample evidence, the method was additionally evaluated on the public Taylor half-hourly electricity-demand series for England and Wales (4,032 observations), using the first 3,360 points for estimation and the final 672 points for testing. For the one-step model, the mean absolute error (MAE) was 429.1 MW, the root mean square error (RMSE) was 574.5 MW, and the mean absolute percentage error (MAPE) was 1.45%. The residual-calibrated, time-of-day triangular spreads had an empirical coverage of 91.7% at α = 0.5 and a mean interval width of 1,804.4 MW. An example of demand-response data is given in the form of a 1 MW effort to reduce base load at four defined hours. Assuming a marginal rate of 0.7 tCO₂/MWh, this gross avoided emission would correspond to an estimate of 2.8 tCO₂ not a quantifiable system benefit measurement. The findings favour interpretability and low computational complexity, but practical deployment requires calibrated margins; energy-neutrality or rebound constraints; larger multi-zone trials; and more specific marginal-emission data.

Clean Energy Science and Technology
Climate action, Affordable and clean energy, Industry, innovation and infrastructure
Energy Load and Power Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon