Switching Overvoltages in High-Speed EMUs Considering VCB Arc Characteristics

Switching operations of onboard vacuum circuit breakers (VCBs) during electrical phase separation can induce transient overvoltages in high-speed electric multiple units (EMUs). This study develops a PSCAD/EMTDC model of the CR400AF high-voltage system, incorporating a combined Mayr–Cassie dynamic arc model for opening and a time-varying resistance model for closing. The voltage responses at the pantograph terminal (P1), VCB output terminal (P2), and traction transformer high-voltage input (P3) are investigated, together with the effects of switching phase and contact movement speed. Under representative switching conditions, the simulated voltage peaks at P1, P2, and P3 were 341.96, 63.95, and 38.90 kV during closing at 90∘, respectively, compared with 208.79, 77.08, and 54.71 kV during opening at 0∘. During closing, the maximum voltage rate of rise at P1 reached 1827.15 kV/μs. Phase scans show higher closing overvoltages near 90∘ and 270∘, but higher opening overvoltages near 0∘ and 180∘. Over a contact-speed range of 0.5–2.0 m/s, the largest closing and opening peaks occur at 0.6 and 1.8 m/s, respectively. A parameter perturbation analysis shows that simultaneous variations of ±10% in the selected flexible-conductor RLC parameters result in peak-voltage deviations below 5% under the representative opening and closing conditions. A nine-case multifactor study of closing phase, contact speed, and distributed parameters further identifies peak voltages ranging from 229.09 to 341.96 kV within the investigated combinations. These results characterize operation-dependent voltage distributions and parameter effects, supporting the assessment of transient voltage stresses in onboard high-voltage equipment.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-13
DOI
https://doi.org/10.3390/app162211272
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Switching Overvoltages in High-Speed EMUs Considering VCB Arc Characteristics

Hao Yang, Cong Wu, Fuqiang Tian, Wantao Xu et al.
Applied Sciences
Electrical Contact Performance and Analysis
article

Switching Overvoltages in High-Speed EMUs Considering VCB Arc Characteristics

Hao Yang, Cong Wu, Fuqiang Tian, Wantao Xu, Hongyu Ge, Xiaoqian Liu
article en

Abstract

Switching operations of onboard vacuum circuit breakers (VCBs) during electrical phase separation can induce transient overvoltages in high-speed electric multiple units (EMUs). This study develops a PSCAD/EMTDC model of the CR400AF high-voltage system, incorporating a combined Mayr–Cassie dynamic arc model for opening and a time-varying resistance model for closing. The voltage responses at the pantograph terminal (P1), VCB output terminal (P2), and traction transformer high-voltage input (P3) are investigated, together with the effects of switching phase and contact movement speed. Under representative switching conditions, the simulated voltage peaks at P1, P2, and P3 were 341.96, 63.95, and 38.90 kV during closing at 90∘, respectively, compared with 208.79, 77.08, and 54.71 kV during opening at 0∘. During closing, the maximum voltage rate of rise at P1 reached 1827.15 kV/μs. Phase scans show higher closing overvoltages near 90∘ and 270∘, but higher opening overvoltages near 0∘ and 180∘. Over a contact-speed range of 0.5–2.0 m/s, the largest closing and opening peaks occur at 0.6 and 1.8 m/s, respectively. A parameter perturbation analysis shows that simultaneous variations of ±10% in the selected flexible-conductor RLC parameters result in peak-voltage deviations below 5% under the representative opening and closing conditions. A nine-case multifactor study of closing phase, contact speed, and distributed parameters further identifies peak voltages ranging from 229.09 to 341.96 kV within the investigated combinations. These results characterize operation-dependent voltage distributions and parameter effects, supporting the assessment of transient voltage stresses in onboard high-voltage equipment.

Applied SciencesVol. 16(22)
Beijing Jiaotong University (CN)
Industry, innovation and infrastructure
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon