Clinical and Finite Element Evaluation of Fixed Implant Prosthesis Designs for the Edentulous Mandible
OBJECTIVE: This study aimed to evaluate the longitudinal clinical outcomes and biomechanical characteristics of various mandibular fixed implant-supported prostheses, focusing on cantilever presence, implant quantity, bone density, and framework materials. METHODS: A retrospective clinical analysis and finite element analysis (FEA) were synthesized. The clinical cohorts of 17 patients were grouped by prosthetic design (cantilever versus non-cantilever) to assess cumulative survival rates (CSR), marginal bone loss (MBL), technical complication rates, and bone density loss (BDL) over a 3-year follow-up period. Concurrently, 32 models were simulated for four configurations: All-on-4 with or without cantilevers (C4/A4) and All-on-6 with or without cantilevers (C6/A6). Occlusal loading was simulated across varying bone densities and framework materials. The peri-implant stress and strain were evaluated. RESULTS: Both clinical cohorts showed high 3-year implant CSR. However, cantilever group exhibited significantly higher MBL, whereas the between-group difference in BDL varied over time. FEA suggested that distal cantilevers amplified peri-implant stress and strain. In cases of posterior bone deficiency, the C6 design yielded more favorable biomechanical performance than the A4 configuration. While Type I bone reduced strain in FEA, no significant association was detected between clinical bone type and either MBL or BDL. Zirconia framework more effectively minimized peri-implant stress and strain than polymethyl methacrylate. CONCLUSIONS: While both prosthetic designs yield acceptable short-term survival rates, cantilever configurations showed higher simulated implant stress and peri-implant bone strain, consistent with the greater MBL observed in the clinical cantilever group. In cases of posterior bone deficiency, a six-implant design with a short cantilever may distribute stress more effectively than utilizing a highly tilted four-implant configuration.
Authors
- Xuejiao Chen (ORCID: https://orcid.org/0000-0001-9908-9006)
- Siyi Chen (ORCID: https://orcid.org/0000-0001-7604-9140)
- Xiaoni Ma (ORCID: https://orcid.org/0000-0002-2929-1046)
- Yuqing Wang (ORCID: https://orcid.org/0009-0007-7012-1173)
- Wenhao Zhao (ORCID: https://orcid.org/0009-0007-6945-9564)
- Wenqian Yu
- Fangyu Zhou
Institutions
- Shandong University (CN)
- Shandong Provincial Hospital (CN)
- Shandong First Medical University (CN)
Publication Details
- Journal
- Clinical Implant Dentistry and Related Research
- Published
- 2026-11-13
- DOI
- https://doi.org/10.1111/cid.70194
- Primary Topic
- Dental Implant Techniques and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Shandong University
- Natural Science Foundation of Shandong Province
- Shandong First Medical University