Clinical and Finite Element Evaluation of Fixed Implant Prosthesis Designs for the Edentulous Mandible

OBJECTIVE: This study aimed to evaluate the longitudinal clinical outcomes and biomechanical characteristics of various mandibular fixed implant-supported prostheses, focusing on cantilever presence, implant quantity, bone density, and framework materials. METHODS: A retrospective clinical analysis and finite element analysis (FEA) were synthesized. The clinical cohorts of 17 patients were grouped by prosthetic design (cantilever versus non-cantilever) to assess cumulative survival rates (CSR), marginal bone loss (MBL), technical complication rates, and bone density loss (BDL) over a 3-year follow-up period. Concurrently, 32 models were simulated for four configurations: All-on-4 with or without cantilevers (C4/A4) and All-on-6 with or without cantilevers (C6/A6). Occlusal loading was simulated across varying bone densities and framework materials. The peri-implant stress and strain were evaluated. RESULTS: Both clinical cohorts showed high 3-year implant CSR. However, cantilever group exhibited significantly higher MBL, whereas the between-group difference in BDL varied over time. FEA suggested that distal cantilevers amplified peri-implant stress and strain. In cases of posterior bone deficiency, the C6 design yielded more favorable biomechanical performance than the A4 configuration. While Type I bone reduced strain in FEA, no significant association was detected between clinical bone type and either MBL or BDL. Zirconia framework more effectively minimized peri-implant stress and strain than polymethyl methacrylate. CONCLUSIONS: While both prosthetic designs yield acceptable short-term survival rates, cantilever configurations showed higher simulated implant stress and peri-implant bone strain, consistent with the greater MBL observed in the clinical cantilever group. In cases of posterior bone deficiency, a six-implant design with a short cantilever may distribute stress more effectively than utilizing a highly tilted four-implant configuration.

Authors

Institutions

Publication Details

Journal
Clinical Implant Dentistry and Related Research
Published
2026-11-13
DOI
https://doi.org/10.1111/cid.70194
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Clinical and Finite Element Evaluation of Fixed Implant Prosthesis Designs for the Edentulous Mandible

Xuejiao Chen, Siyi Chen, Xiaoni Ma, Yuqing Wang et al.
2 links
Clinical Implant Dentistry and Related Research
Dental Implant Techniques and Outcomes
article

Clinical and Finite Element Evaluation of Fixed Implant Prosthesis Designs for the Edentulous Mandible

Xuejiao Chen, Siyi Chen, Xiaoni Ma, Yuqing Wang, Wenhao Zhao, Wenqian Yu, Fangyu Zhou
article en

Abstract

OBJECTIVE: This study aimed to evaluate the longitudinal clinical outcomes and biomechanical characteristics of various mandibular fixed implant-supported prostheses, focusing on cantilever presence, implant quantity, bone density, and framework materials. METHODS: A retrospective clinical analysis and finite element analysis (FEA) were synthesized. The clinical cohorts of 17 patients were grouped by prosthetic design (cantilever versus non-cantilever) to assess cumulative survival rates (CSR), marginal bone loss (MBL), technical complication rates, and bone density loss (BDL) over a 3-year follow-up period. Concurrently, 32 models were simulated for four configurations: All-on-4 with or without cantilevers (C4/A4) and All-on-6 with or without cantilevers (C6/A6). Occlusal loading was simulated across varying bone densities and framework materials. The peri-implant stress and strain were evaluated. RESULTS: Both clinical cohorts showed high 3-year implant CSR. However, cantilever group exhibited significantly higher MBL, whereas the between-group difference in BDL varied over time. FEA suggested that distal cantilevers amplified peri-implant stress and strain. In cases of posterior bone deficiency, the C6 design yielded more favorable biomechanical performance than the A4 configuration. While Type I bone reduced strain in FEA, no significant association was detected between clinical bone type and either MBL or BDL. Zirconia framework more effectively minimized peri-implant stress and strain than polymethyl methacrylate. CONCLUSIONS: While both prosthetic designs yield acceptable short-term survival rates, cantilever configurations showed higher simulated implant stress and peri-implant bone strain, consistent with the greater MBL observed in the clinical cantilever group. In cases of posterior bone deficiency, a six-implant design with a short cantilever may distribute stress more effectively than utilizing a highly tilted four-implant configuration.

Clinical Implant Dentistry and Related ResearchVol. 28(6)
Shandong University (CN), Shandong Provincial Hospital (CN), Shandong First Medical University (CN)
Shandong University, Natural Science Foundation of Shandong Province, Shandong First Medical University
Good health and well-being
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon