Modified robotic atrial septal defect repair on beating heart: a nine-year single-centre experience with learning-curve analysis and comparison with thoracoscopy

Abstract Objective To evaluate a modified robot-assisted technique for atrial septal defect (ASD) repair on beating heart and to compare perioperative outcomes with thoracoscopic repair. Methods 198 patients with ASD underwent modified ASD repair using the Da Vinci robotic surgical system on beating heart in the Department of Cardiovascular Surgery of the First Affiliated Hospital with Nanjing Medical University. Cumulative sum (CUSUM) analysis was used to build learning curves for operation time and cardiopulmonary bypass (CPB) time. Patients operated after both curves had plateaued formed the robotic group (n = 117); 113 patients treated thoracoscopically during the same period served as the comparison group. Results The learning curves for operation time and CPB time were 81 cases and 66 cases respectively. ASD diameter and pulmonary artery systolic pressure were higher in the robotic group, which also contained seven patients with partial anomalous pulmonary venous connection (PAPVC) and one with anomalous drainage of the inferior vena cava. CPB time was shorter in the robotic group. Operation time, mechanical ventilation time, intensive care unit stay, postoperative hospital stay and 24-hour chest drainage did not differ. Echocardiography at 3, 30 and 90 days and at one year showed no residual shunt or tricuspid regurgitation in either group. Conclusions The modified robot-assisted technique for beating-heart ASD repair is safe and reproducible. Once the learning curve is complete, CPB time is shorter than with thoracoscopy despite greater anatomical complexity, and the technique offers a valid minimally invasive option for defects that are unsuitable for device closure.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-13
DOI
https://doi.org/10.21203/rs.3.rs-11427977/v1
Primary Topic
Congenital Heart Disease Studies
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Modified robotic atrial septal defect repair on beating heart: a nine-year single-centre experience with learning-curve analysis and comparison with thoracoscopy

吴延虎, Yihu Tang, Yawei Dai, Hanchao Feng et al.
Research Square
Congenital Heart Disease Studies
preprint

Modified robotic atrial septal defect repair on beating heart: a nine-year single-centre experience with learning-curve analysis and comparison with thoracoscopy

吴延虎, Yihu Tang, Yawei Dai, Hanchao Feng, JinMo Kong, Mingke Li
preprint en

Abstract

Abstract Objective To evaluate a modified robot-assisted technique for atrial septal defect (ASD) repair on beating heart and to compare perioperative outcomes with thoracoscopic repair. Methods 198 patients with ASD underwent modified ASD repair using the Da Vinci robotic surgical system on beating heart in the Department of Cardiovascular Surgery of the First Affiliated Hospital with Nanjing Medical University. Cumulative sum (CUSUM) analysis was used to build learning curves for operation time and cardiopulmonary bypass (CPB) time. Patients operated after both curves had plateaued formed the robotic group (n = 117); 113 patients treated thoracoscopically during the same period served as the comparison group. Results The learning curves for operation time and CPB time were 81 cases and 66 cases respectively. ASD diameter and pulmonary artery systolic pressure were higher in the robotic group, which also contained seven patients with partial anomalous pulmonary venous connection (PAPVC) and one with anomalous drainage of the inferior vena cava. CPB time was shorter in the robotic group. Operation time, mechanical ventilation time, intensive care unit stay, postoperative hospital stay and 24-hour chest drainage did not differ. Echocardiography at 3, 30 and 90 days and at one year showed no residual shunt or tricuspid regurgitation in either group. Conclusions The modified robot-assisted technique for beating-heart ASD repair is safe and reproducible. Once the learning curve is complete, CPB time is shorter than with thoracoscopy despite greater anatomical complexity, and the technique offers a valid minimally invasive option for defects that are unsuitable for device closure.

Research Square
Jiangsu Province Hospital (CN), Yangzhou University (CN), Nanjing Medical University (CN)
Government of Jiangsu Province
Good health and well-being
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon