Seismic performance of prefabricated self-centering frame structure: shaking table test and simulation

Abstract The seismic performance of a prefabricated self-centering frame comprising concrete-filled double-skin steel tube (CFDST) columns, precast reinforced concrete main beams, prestressed steel strands, and friction energy-dissipation devices was investigated through shaking-table tests and numerical analyses. The beam steel strands were tensioned during prefabrication to eliminate on-site tensioning. A half-scale, two-story, two-bay specimen was subjected to five ground motions at four nominal acceleration levels. Floor acceleration and displacement responses, column base and beam-to-column interface openings, and strains in reinforcement, concrete surfaces, ring plates, and connecting I-section steels were examined. Peak accelerations, displacements, interface openings, and strains generally increased with input intensity, with larger floor responses occurring at the second story. The Tianjin wave produced the largest second-floor peak accelerations from 0.20 to 0.40 g. At 0.40 g, the mean peak column base and beam-to-column openings reached 2.82 and 3.14 mm, respectively. The maximum interstory drift ratio reached 1/33, while residual floor displacements remained below 2 mm. Mean peak strains were generally larger at the first story. An OpenSees model reproduced the measured initial frequencies and principal features of acceleration and displacement histories. Parametric analyses under the El Centro wave showed that increasing beam steel strand prestress raised the first-mode frequency by 13.8%, increasing column steel strand prestress from 250 to 893 MPa reduced calculated residual displacement by approximately 95%, and increasing initial bolt torque reduced calculated maximum displacement by 54%. These findings clarify the frame response and the contributions of prestress and friction resistance to seismic response control.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-13
DOI
https://doi.org/10.21203/rs.3.rs-11552235/v1
Primary Topic
Seismic Performance and Analysis
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Seismic performance of prefabricated self-centering frame structure: shaking table test and simulation

Xueyuan Yan, Genliang Wang, Taoyuan Ren, Chongjie Zhang et al.
4 links
Research Square
Seismic Performance and Analysis
preprint

Seismic performance of prefabricated self-centering frame structure: shaking table test and simulation

Xueyuan Yan, Genliang Wang, Taoyuan Ren, Chongjie Zhang, Jitao Yu, Zhongnan Lin, Jie Zheng
preprint en

Abstract

Abstract The seismic performance of a prefabricated self-centering frame comprising concrete-filled double-skin steel tube (CFDST) columns, precast reinforced concrete main beams, prestressed steel strands, and friction energy-dissipation devices was investigated through shaking-table tests and numerical analyses. The beam steel strands were tensioned during prefabrication to eliminate on-site tensioning. A half-scale, two-story, two-bay specimen was subjected to five ground motions at four nominal acceleration levels. Floor acceleration and displacement responses, column base and beam-to-column interface openings, and strains in reinforcement, concrete surfaces, ring plates, and connecting I-section steels were examined. Peak accelerations, displacements, interface openings, and strains generally increased with input intensity, with larger floor responses occurring at the second story. The Tianjin wave produced the largest second-floor peak accelerations from 0.20 to 0.40 g. At 0.40 g, the mean peak column base and beam-to-column openings reached 2.82 and 3.14 mm, respectively. The maximum interstory drift ratio reached 1/33, while residual floor displacements remained below 2 mm. Mean peak strains were generally larger at the first story. An OpenSees model reproduced the measured initial frequencies and principal features of acceleration and displacement histories. Parametric analyses under the El Centro wave showed that increasing beam steel strand prestress raised the first-mode frequency by 13.8%, increasing column steel strand prestress from 250 to 893 MPa reduced calculated residual displacement by approximately 95%, and increasing initial bolt torque reduced calculated maximum displacement by 54%. These findings clarify the frame response and the contributions of prestress and friction resistance to seismic response control.

Research Square
Fuzhou University (CN)
National Natural Science Foundation of China, Science and Technology Planning Project of Fuzhou
Industry, innovation and infrastructure
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon