Seismic amplitude of the reservoir-top reflection indicates gas flow where logs and core do not: calibrating 3D seismic attributes against drill-stem tests in a tight fractured quartzite, Attahaddy Field, Sirte Basin, Libya
Abstract In the Cambro-Ordovician Gargaf quartzite of the Attahaddy gas field, Sirte Basin, Libya, porosity is about 3%, most core plugs have no measurable permeability, and neither logs nor core predict which drill-stem tests (DSTs) flow gas. We test whether 3D seismic amplitude does, computing all attributes directly from the SEG-Y volume. The DST labels were first audited against the written test results: field-wide, four tests recorded as tight had flowed gas through a choke and three were invalid because the packer failed. Over the corrected set of 59 gas-flowing or tight Gargaf DSTs in 27 wells, the average positive peak value in the 0–20 ms window below the Gargaf pick, chosen before the labels were corrected, is higher at gas-flowing tests (median 3,276 against 1,890; p = 0.004) and raises the leave-one-well-out AUC of a model of test depth and interval length from 0.825 to 0.874 (permutation p = 0.034), although the bootstrap interval of this gain includes zero. A scan of 78 windows locates the signal in the top-reflection complex: every window that improves the model by 0.05 or more overlaps it, while windows in the overburden or more than 40 ms inside the quartzite add no predictive value. The window spanning the whole complex, from 20 ms above to 40 ms below the pick, raises the AUC to 0.992 (0.98–0.99 when whole areas of the field are left out), and remains significant when the window search is repeated inside every permutation (p = 0.035). Gas-flowing intervals extend deeper where this reflection is bright. Neither the fluid nor the borehole-scale impedance contrast explains the amplitude, and a fracture-spacing model fitted to the same DSTs gives conductive fractures about 120 ft apart along the hole where the top reflection is bright and about 430 ft where it is dim (p = 0.003). We interpret the amplitude as a seismic-scale proxy for open-fracture density below the unconformity. Only three of the 27 wells never flowed gas, so the well-level evidence is weak and confirmation in more wells is needed; within that limit, the top reflection is the first measurement in this field that adds information on flow beyond structural position.
Authors
- Gheith Alfakri
Publication Details
- Journal
- Research Square
- Published
- 2026-11-13
- DOI
- https://doi.org/10.21203/rs.3.rs-11511991/v1
- Primary Topic
- Hydrocarbon exploration and reservoir analysis
- Type
- preprint