Multiple-Pedicle Peroneal Artery Perforator Propeller Flap for Distal Lower Extremity Reconstruction: Technical Considerations and Preliminary Clinical Outcomes

Background and Objectives: Peroneal artery perforator-based propeller flaps are widely used for reconstruction of distal lower extremity defects. However, venous congestion remains a frequent complication of single pedicle propeller flaps, with reported rates of approximately 15% to over 30%. The clustered perforator anatomy of the peroneal artery may allow incorporation of multiple pedicles within a single propeller flap. This study evaluated the feasibility of multiple pedicle peroneal artery perforator propeller flaps for ankle and distal foot reconstruction. Materials and Methods: This retrospective case series included five patients who underwent reconstruction using multiple pedicle peroneal artery perforator propeller flaps between January 2017 and December 2021. Defect characteristics, number of incorporated perforators, interpedicle distance, rotation angle, and clinical outcomes were reviewed. Results: The cohort consisted of four males and one female (mean age, 47.4 years). Defects involved the lateral ankle (n = 3), anterolateral ankle (n = 1), and posterior foot (n = 1), with sizes ranging from 16 to 30 cm2 (mean, 23.6 cm2). Four flaps incorporated two perforators, and one incorporated three perforators. Interpedicle distances ranged from 32 to 37 mm. Flap rotation ranged from 120° to 180°. None of the cases demonstrated venous congestion, arterial insufficiency, partial necrosis, or total flap loss. All wounds healed within 3–4 weeks (mean, 3.6 weeks). Conclusions: Multiple pedicle peroneal artery perforator propeller flaps were technically feasible in this small case series, with complete flap survival and no vascular complications observed among the five patients. Given the small sample size and retrospective design, these findings should be interpreted as preliminary clinical observations rather than evidence of generalized safety or superiority over conventional single-perforator propeller flaps.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2026-11-13
DOI
https://doi.org/10.3390/medicina62112221
Primary Topic
Reconstructive Surgery and Microvascular Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multiple-Pedicle Peroneal Artery Perforator Propeller Flap for Distal Lower Extremity Reconstruction: Technical Considerations and Preliminary Clinical Outcomes

Il‐Jung Park, Jin‐Hyung Im, Joo‐Yup Lee, Youn-Tae Roh et al.
Medicina
Reconstructive Surgery and Microvascular Techniques
article

Multiple-Pedicle Peroneal Artery Perforator Propeller Flap for Distal Lower Extremity Reconstruction: Technical Considerations and Preliminary Clinical Outcomes

Il‐Jung Park, Jin‐Hyung Im, Joo‐Yup Lee, Youn-Tae Roh, Won-Jae Seo
article en

Abstract

Background and Objectives: Peroneal artery perforator-based propeller flaps are widely used for reconstruction of distal lower extremity defects. However, venous congestion remains a frequent complication of single pedicle propeller flaps, with reported rates of approximately 15% to over 30%. The clustered perforator anatomy of the peroneal artery may allow incorporation of multiple pedicles within a single propeller flap. This study evaluated the feasibility of multiple pedicle peroneal artery perforator propeller flaps for ankle and distal foot reconstruction. Materials and Methods: This retrospective case series included five patients who underwent reconstruction using multiple pedicle peroneal artery perforator propeller flaps between January 2017 and December 2021. Defect characteristics, number of incorporated perforators, interpedicle distance, rotation angle, and clinical outcomes were reviewed. Results: The cohort consisted of four males and one female (mean age, 47.4 years). Defects involved the lateral ankle (n = 3), anterolateral ankle (n = 1), and posterior foot (n = 1), with sizes ranging from 16 to 30 cm2 (mean, 23.6 cm2). Four flaps incorporated two perforators, and one incorporated three perforators. Interpedicle distances ranged from 32 to 37 mm. Flap rotation ranged from 120° to 180°. None of the cases demonstrated venous congestion, arterial insufficiency, partial necrosis, or total flap loss. All wounds healed within 3–4 weeks (mean, 3.6 weeks). Conclusions: Multiple pedicle peroneal artery perforator propeller flaps were technically feasible in this small case series, with complete flap survival and no vascular complications observed among the five patients. Given the small sample size and retrospective design, these findings should be interpreted as preliminary clinical observations rather than evidence of generalized safety or superiority over conventional single-perforator propeller flaps.

MedicinaVol. 62(11)
Eunpyeong Hospital (KR), The Catholic University of Korea Yeouido St. Mary's Hospital (KR), The Catholic University of Korea Bucheon St. Mary's Hospital (KR), The Catholic University of Korea Seoul St. Mary's Hospital (KR), Catholic University of Korea (KR)
Good health and well-being
Reconstructive Surgery and Microvascular Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon