An integrated contact-aware cobot design for accurate UAV battery docking and battery swapping

Abstract This research introduces a integrated design and evaluation methodology for a lightweight, contact-aware cobot for autonomous battery swapping of Unmanned Aerial Vehicles (UAVs). It involves Denavit–Hartenberg kinematics, inverse kinematics, quintic trajectory generation, inverse dynamics, actuator torque sizing, structural verification, modal assessment, gripping-force estimation, connector-compression modeling, passive wrist compliance, docking-misalignment sensitivity, and a Battery-Swapping Cobot Performance Index (BS-CPI). The six-degree-of-freedoms manipulator was modeled under the following conditions: 3.5 kg of battery-gripper load and a working reach of 0.88 m. The nominal trajectory generated an estimated peak simulated torque of 24.97 Nm at the shoulder pitch joint, which was identified as the critical actuator location by conservative torque sizing with a required torque of 142.61 Nm and a rated torque of 220 Nm. The maximum link deflection was 0.177 mm and the minimum preliminary factor of safety was 56.97 from the structural evaluation. There was no force exceeding the safe limit of 45 N in the controlled insertion force for the contact-aware insertion model and connector compression was limited to 6 mm. Sensitivity analysis also indicated that the combination of lateral and yaw misalignment resulted in higher insertion forces and only caused the retries under extreme misalignment. The final performance index was 0.498, which showed a reasonable compromise between mass, torque demand, insertion safety, stiffness and cycle performance. The study provides a tabular computational conceptualization as a traceable pre-prototype basis for developing autonomous UAV battery-swapping stations that engage connectors in a safe manner, handle them repeatably, and have quantified tolerance to docking misalignment.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-13
DOI
https://doi.org/10.1038/s41598-026-76160-1
Primary Topic
Robotic Mechanisms and Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An integrated contact-aware cobot design for accurate UAV battery docking and battery swapping

Thenkaraimuthu Mariprasath, Lalu Gladson Robin, Mengistu Zelalem Zewdu, S. K. Remmi
1 links
Scientific Reports
Robotic Mechanisms and Dynamics
article

An integrated contact-aware cobot design for accurate UAV battery docking and battery swapping

Thenkaraimuthu Mariprasath, Lalu Gladson Robin, Mengistu Zelalem Zewdu, S. K. Remmi
article en

Abstract

Abstract This research introduces a integrated design and evaluation methodology for a lightweight, contact-aware cobot for autonomous battery swapping of Unmanned Aerial Vehicles (UAVs). It involves Denavit–Hartenberg kinematics, inverse kinematics, quintic trajectory generation, inverse dynamics, actuator torque sizing, structural verification, modal assessment, gripping-force estimation, connector-compression modeling, passive wrist compliance, docking-misalignment sensitivity, and a Battery-Swapping Cobot Performance Index (BS-CPI). The six-degree-of-freedoms manipulator was modeled under the following conditions: 3.5 kg of battery-gripper load and a working reach of 0.88 m. The nominal trajectory generated an estimated peak simulated torque of 24.97 Nm at the shoulder pitch joint, which was identified as the critical actuator location by conservative torque sizing with a required torque of 142.61 Nm and a rated torque of 220 Nm. The maximum link deflection was 0.177 mm and the minimum preliminary factor of safety was 56.97 from the structural evaluation. There was no force exceeding the safe limit of 45 N in the controlled insertion force for the contact-aware insertion model and connector compression was limited to 6 mm. Sensitivity analysis also indicated that the combination of lateral and yaw misalignment resulted in higher insertion forces and only caused the retries under extreme misalignment. The final performance index was 0.498, which showed a reasonable compromise between mass, torque demand, insertion safety, stiffness and cycle performance. The study provides a tabular computational conceptualization as a traceable pre-prototype basis for developing autonomous UAV battery-swapping stations that engage connectors in a safe manner, handle them repeatably, and have quantified tolerance to docking misalignment.

Scientific Reports
ASA College (US), Gambella University (ET), Noorul Islam University (IN)
Industry, innovation and infrastructure
Robotic Mechanisms and Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon