Dynamic chlorine vacancies enable X-ray-specific afterglow

Afterglow luminescence in inorganic materials is conventionally attributed to pre-existing static defects that trap and gradually release charge carriers. However, the observation of afterglow activated only by specific types of excitation sources, such as X-ray-specific afterglow in certain phosphors, highlights an opportunity to move beyond this static trap model. Here we show that Bi3+ doped Cs2ZrCl6 crystals exhibit afterglow exclusively under X-ray excitation, with no such effect under ultraviolet illumination. We demonstrate that this behavior arises from the in-situ generation and self-healing of metastable chlorine vacancies (VCl) specifically driven by X-ray irradiation, directly correlating with afterglow kinetics. Advancing beyond previous vague attributions to Frenkel defects, our multimodal evidence unambiguously pinpoints VCl as the operative defect species. This discovery challenges the paradigm that afterglow requires static pre-existing traps, establishing a dynamic mechanism where metastable defects are created by the probing radiation and gradually disappear when radiation is removed. We further manipulate the afterglow kinetic through Sn4+ induced modulation of vacancy formation energy, extending the afterglow duration to multiple hours while maintaining a high light yield of 55670 photons MeV−1 and a low detection limit of 30.81 nGyair s−1. Finally, we integrate these crystals into a flexible PDMS composite film for X-ray imaging, achieving a high spatial resolution of 23.6 lp mm−1 that enables high-fidelity imaging of curved objects via time-resolved readout. Our findings open an avenue for designing smart scintillators with programmable, radiation-specific responses, with implications for flexible radiography and beyond. Afterglow is thought to arise from permanent charge-trapping defects, yet radiation-specific responses defy this model. Liu et al. reveal that X-rays create transient chlorine vacancies and control their formation for prolonged, high-resolution flexible imaging.

Authors

Institutions

Publication Details

Journal
Nature Communications
Published
2026-11-13
DOI
https://doi.org/10.1038/s41467-026-79525-2
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Dynamic chlorine vacancies enable X-ray-specific afterglow

Yunfei Shang, Shuwei Hao, Jiajia Zhou, Deyang Li et al.
Nature Communications
Radiation Detection and Scintillator Technologies
article

Dynamic chlorine vacancies enable X-ray-specific afterglow

Yunfei Shang, Shuwei Hao, Jiajia Zhou, Deyang Li, Chunhui Yang, Huilin Liu, QianQian Zhao, Peng Gao
article en

Abstract

Afterglow luminescence in inorganic materials is conventionally attributed to pre-existing static defects that trap and gradually release charge carriers. However, the observation of afterglow activated only by specific types of excitation sources, such as X-ray-specific afterglow in certain phosphors, highlights an opportunity to move beyond this static trap model. Here we show that Bi3+ doped Cs2ZrCl6 crystals exhibit afterglow exclusively under X-ray excitation, with no such effect under ultraviolet illumination. We demonstrate that this behavior arises from the in-situ generation and self-healing of metastable chlorine vacancies (VCl) specifically driven by X-ray irradiation, directly correlating with afterglow kinetics. Advancing beyond previous vague attributions to Frenkel defects, our multimodal evidence unambiguously pinpoints VCl as the operative defect species. This discovery challenges the paradigm that afterglow requires static pre-existing traps, establishing a dynamic mechanism where metastable defects are created by the probing radiation and gradually disappear when radiation is removed. We further manipulate the afterglow kinetic through Sn4+ induced modulation of vacancy formation energy, extending the afterglow duration to multiple hours while maintaining a high light yield of 55670 photons MeV−1 and a low detection limit of 30.81 nGyair s−1. Finally, we integrate these crystals into a flexible PDMS composite film for X-ray imaging, achieving a high spatial resolution of 23.6 lp mm−1 that enables high-fidelity imaging of curved objects via time-resolved readout. Our findings open an avenue for designing smart scintillators with programmable, radiation-specific responses, with implications for flexible radiography and beyond. Afterglow is thought to arise from permanent charge-trapping defects, yet radiation-specific responses defy this model. Liu et al. reveal that X-rays create transient chlorine vacancies and control their formation for prolonged, high-resolution flexible imaging.

Nature Communications
University of Technology Sydney (AU), Harbin Institute of Technology (CN), China Jiliang University (CN)
Heilongjiang University, National Natural Science Foundation of China, China Postdoctoral Science Foundation, Harbin Institute of Technology, Natural Science Foundation of Chongqing, Fundamental Research Funds for the Central Universities
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon