Smooth Subband Entropy and Time-Domain Feature Fusion for Personalized Lower-Limb Movement Recognition
Surface electromyography (sEMG) supports personalized movement recognition, but feature utility must be interpreted together with preprocessing conditions. We evaluated a task-specific integration of a smooth fast Fourier transform (FFT) subband bank, nearest-neighbor entropy (NNE), time-domain (TD) descriptors, and participant-specific extreme gradient boosting (XGBoost). Nine-channel recordings from 40 Shenzhen Institute of Advanced Technology Lower Limb Motion Dataset (SIAT-LLMD) participants were evaluated for 16-class recognition using repetition-grouped five-fold cross-validation. Under complete-record amplitude normalization, the 216-dimensional fusion achieved 95.63% accuracy and 94.54% macro-F1, exceeding TD-XGB by 1.043 percentage points; random and repeated-feature expansion did not reproduce this gain. With the classifier configurations held fixed, macro-F1 was 94.85% with record-specific references fitted to all eligible samples, 95.58% with record-specific training-only references, and 75.31% with shared participant-level training references. The record-specific controls require movement-associated recording identity and do not establish prospective unknown-action performance. This gain was accompanied by median single-thread CPU computation of 34.210 ms per conditioned window for Fusion-XGB, compared with 5.392 ms for TD-XGB (approximately sixfold). Across the evaluated amplitude-reference conditions, Fusion-XGB retained a macro-F1 improvement over TD-XGB, while absolute recognition performance varied with the reference definition.
Authors
- Chun Zheng (ORCID: https://orcid.org/0000-0003-3089-6453)
- Zhanfeng Ying (ORCID: https://orcid.org/0000-0002-8789-3758)
- Zhengui Huang (ORCID: https://orcid.org/0000-0003-0163-4649)
- Zhihua Chen (ORCID: https://orcid.org/0000-0003-1455-674X)
- Wenbo Chen (ORCID: https://orcid.org/0009-0003-0194-7108)
- Jiang Chang (ORCID: https://orcid.org/0009-0007-3524-1401)
- Fengrong Tang (ORCID: https://orcid.org/0009-0001-5694-2780)
Institutions
- Southern University of Science and Technology (CN)
- Nanjing University of Science and Technology (CN)
- National Key Laboratory of Transient Physics (CN)
Publication Details
- Journal
- Sensors
- Published
- 2026-11-13
- DOI
- https://doi.org/10.3390/s26227182
- Primary Topic
- Muscle activation and electromyography studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00