An Atmospheric Water and Acid Harvesting Condenser for Venus: Collection Rate and Cooling Sizing
This study sizes an Atmospheric Water and Acid Harvesting Condenser for Venus for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted. Among the computed results are atmospheric water vapour abundance of 20.0 parts per million, air processed per day of 52000.0 kilograms, gross water collected of 0.425 kilograms per day, net water collected of 0.264 kilograms per day. Mass and power budgets are assembled from components so that they can be audited, off-design behaviour and materials uncertainty are discussed openly, and the limits of the sizing are stated in full. The system is a civilian science and construction design intended for a robotically serviced surface station.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-13
- DOI
- https://doi.org/10.5281/zenodo.24199721
- Citations
- 1
- Primary Topic
- Solar-Powered Water Purification Methods
- Type
- article
- Field-Weighted Citation Impact
- 0.80