A Nitrogen Liquefaction Plant for a Titan Surface Station: Refrigeration Duty and Production Sizing

This study sizes the Titan surface system named in its title for operation in the Titan surface environment, and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted. Among the computed results are cooling duty per kilogram of product of 214.6 kilojoules per kilogram, total cooling duty at rated production of 124.2 watts, Carnot coefficient of performance of 5.27. Mass and power budgets are assembled from components so that they can be audited, off-design behaviour and materials uncertainty are discussed openly, and the limits of the sizing are stated in full. The plant is civilian station infrastructure that liquefies atmospheric nitrogen for cryogenic storage, sample preservation and industrial use at the station; it is a refrigeration plant with no application beyond supporting peaceful surface operations.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24203126
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Nitrogen Liquefaction Plant for a Titan Surface Station: Refrigeration Duty and Production Sizing

William Alexander Aldred
11 links
Zenodo (CERN European Organization for Nuclear Research)
Spacecraft and Cryogenic Technologies
article

A Nitrogen Liquefaction Plant for a Titan Surface Station: Refrigeration Duty and Production Sizing

William Alexander Aldred
article en

Abstract

This study sizes the Titan surface system named in its title for operation in the Titan surface environment, and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted. Among the computed results are cooling duty per kilogram of product of 214.6 kilojoules per kilogram, total cooling duty at rated production of 124.2 watts, Carnot coefficient of performance of 5.27. Mass and power budgets are assembled from components so that they can be audited, off-design behaviour and materials uncertainty are discussed openly, and the limits of the sizing are stated in full. The plant is civilian station infrastructure that liquefies atmospheric nitrogen for cryogenic storage, sample preservation and industrial use at the station; it is a refrigeration plant with no application beyond supporting peaceful surface operations.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy, Climate action
Spacecraft and Cryogenic Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon