Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages
Wearable pulse metrics are typically reported as a single daily, waking, or nightly average. This presentation of the data may mask differences between sleep and wakefulness, temporal variations within a given state, and differences in the amount of signal retained. To determine whether single-value averages provide a representative summary of free-living pulse physiology, we analyzed 28 days of smartwatch and smart-ring data from 35 participants. Sleep and waking periods were identified using the smart-ring sleep data. Pulse rate was obtained from the smartwatch-generated values, and pulse rate variability (PRV) was calculated from the raw photoplethysmography as the root mean square of successive pulse-interval differences (RMSSD) and standard deviation of pulse-to-pulse intervals (SDNN). Analyses compared paired sleep–wake periods and examined temporal variability within both waking and sleep periods. Mean pulse rate was 72.4 beats/min during sleep and 89.1 beats/min during the subsequent waking period (difference: −16.7 beats/min; 95% confidence interval [CI], −23.0 to −10.2). The mean absolute deviation of the five-minute waking pulse-rate measurements from the waking-period mean was 10.89 beats/min (95% CI, 9.75–12.02); on average, 44.6% of waking measurements differed from the mean by more than 10 beats/min. During sleep, the mean absolute deviation from the period mean was 4.30 beats/min (95% CI, 3.17–5.56). From earlier to later sleep, RMSSD increased by 40.8% (95% CI, 18.7–67.5%; q = 0.0001) and SDNN increased by 82.6% (95% CI, 51.4–117.4%; q = 0.0001). Only 8.6% of the waking recordings met the PRV quality criteria, whereas 64.0% of the sleep recordings did. In summary, single-value averages may not capture differences between sleep and wakefulness or temporal structure within states; unequal signal retention may also affect the representativeness of state averages. Therefore, reports of wearable pulse biomarkers should specify sleep–wake state, within-state timing, aggregation method, and signal retention criteria.
Authors
- Ruixue Cai (ORCID: https://orcid.org/0000-0001-8641-0753)
- A Rahmani
- Shahab Haghayegh (ORCID: https://orcid.org/0000-0002-7232-2637)
Institutions
- Broad Institute (US)
- Harvard University (US)
- University of California, Irvine (US)
- Massachusetts General Hospital (US)
Publication Details
- Journal
- Journal of Cardiovascular Development and Disease
- Published
- 2026-11-13
- DOI
- https://doi.org/10.3390/jcdd13110589
- Primary Topic
- Heart Rate Variability and Autonomic Control
- Type
- article
- Field-Weighted Citation Impact
- 0.00