Anchoring the reference frame on a rod bridging the pedicle screws: An alternative for intraoperative registration in robot-assisted spine surgery when the spinous processes are absent or fragile

Background: Robot-assisted spine surgery depends on rigid fixation of the robotic system reference frame to the posterior superior iliac spine or spinous processes of the patient. However, if the spinous processes are absent or are fragile, we propose and have successfully utilized a reference clamp anchoring technique affixed to a rod that transversely connects the two pedicle screws of the same vertebra. Methods: We have described and have utilized the clamp anchoring technique to perform robot spine surgery. Results: In a previously operated thoracic segment, the rod-based reference provided stable/successful anchoring sufficient to achieve accurate registration for robot-assisted pedicle screw placement without complications. Conclusion: In the absence or fragility of spinous processes, anchoring the reference frame to a rod bridging two pedicle screws of a single vertebra successfully achieved accurate intraoperative registration to proceed with robotic spine surgery.

Authors

Institutions

Publication Details

Journal
Surgical Neurology International
Published
2026-11-13
DOI
https://doi.org/10.25259/sni_1106_2026
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Anchoring the reference frame on a rod bridging the pedicle screws: An alternative for intraoperative registration in robot-assisted spine surgery when the spinous processes are absent or fragile

Rian Souza Vieira, Otávio da Cunha Ferreira Neto, Vinícius Marques Carneiro, Matheus Pippa Defino et al.
2 links
Surgical Neurology International
Spinal Fractures and Fixation Techniques
article

Anchoring the reference frame on a rod bridging the pedicle screws: An alternative for intraoperative registration in robot-assisted spine surgery when the spinous processes are absent or fragile

Rian Souza Vieira, Otávio da Cunha Ferreira Neto, Vinícius Marques Carneiro, Matheus Pippa Defino, Helton Luíz Aparecido Defino, Denylson Sanches Fernandes, Ricardo Santos de Oliveira
article en

Abstract

Background: Robot-assisted spine surgery depends on rigid fixation of the robotic system reference frame to the posterior superior iliac spine or spinous processes of the patient. However, if the spinous processes are absent or are fragile, we propose and have successfully utilized a reference clamp anchoring technique affixed to a rod that transversely connects the two pedicle screws of the same vertebra. Methods: We have described and have utilized the clamp anchoring technique to perform robot spine surgery. Results: In a previously operated thoracic segment, the rod-based reference provided stable/successful anchoring sufficient to achieve accurate registration for robot-assisted pedicle screw placement without complications. Conclusion: In the absence or fragility of spinous processes, anchoring the reference frame to a rod bridging two pedicle screws of a single vertebra successfully achieved accurate intraoperative registration to proceed with robotic spine surgery.

Surgical Neurology InternationalVol. 17
Universidade de São Paulo (BR)
Good health and well-being
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon