A Static Thermoelectric Backup Generator for Mars Night and Storm Survival Loads: Seebeck Conversion Sizing

This paper presents a sized design for a Mars surface system based on static Seebeck thermoelectric conversion from a radioisotope-free heated block using reactor waste heat as the hot source. A solid-state thermoelectric unit with no moving parts that covers survival loads when dynamic convertors are offline. The study is SIMULATED, NOT MEASURED: all values are computed from stated assumptions and published Martian environmental data, and no hardware was built or tested. The principal computed results are hot side K of 820, cold side K of 320, figure of merit ZT of 1.1, carnot limit of 0.61. Further results include conversion efficiency of 0.1489, heat input W of 4200, electric power W of 625.3, waste heat W of 3574.7. The design is a computed study for peaceful surface operations — power supply, thermal control, radiation protection, construction and resource extraction for a crewed base — and it has no targeting or weapon application. Losses, deratings for dust and temperature, and the margin between capacity and the stated load are reported alongside the headline figures, and the limitations section states what a physical test would still need to establish.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24193799
Citations
1
Primary Topic
Advanced Thermoelectric Materials and Devices
Type
article
Field-Weighted Citation Impact
1.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Static Thermoelectric Backup Generator for Mars Night and Storm Survival Loads: Seebeck Conversion Sizing

William Alexander Aldred
1 citations
Zenodo (CERN European Organization for Nuclear Research)
Advanced Thermoelectric Materials and Devices
1.03
article

A Static Thermoelectric Backup Generator for Mars Night and Storm Survival Loads: Seebeck Conversion Sizing

William Alexander Aldred
article en
1 citations

Abstract

This paper presents a sized design for a Mars surface system based on static Seebeck thermoelectric conversion from a radioisotope-free heated block using reactor waste heat as the hot source. A solid-state thermoelectric unit with no moving parts that covers survival loads when dynamic convertors are offline. The study is SIMULATED, NOT MEASURED: all values are computed from stated assumptions and published Martian environmental data, and no hardware was built or tested. The principal computed results are hot side K of 820, cold side K of 320, figure of merit ZT of 1.1, carnot limit of 0.61. Further results include conversion efficiency of 0.1489, heat input W of 4200, electric power W of 625.3, waste heat W of 3574.7. The design is a computed study for peaceful surface operations — power supply, thermal control, radiation protection, construction and resource extraction for a crewed base — and it has no targeting or weapon application. Losses, deratings for dust and temperature, and the margin between capacity and the stated load are reported alongside the headline figures, and the limitations section states what a physical test would still need to establish.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 33%
Advanced Thermoelectric Materials and Devices
1.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon