Skin‐Interfaced Wearable Device for Synchronically Harvesting High‐Entropy Body Energy and Monitoring Deep Tissue Temperature

ABSTRACT Efficiently harvesting thermal energy from human skin poses formidable challenges owing to its high‐entropy characteristics. While Seebeck‐effect wearable thermoelectric devices can convert skin heat flux into electrical voltage, prevailing generators remain constrained in delivering sustainable energy and multifunctionality. This limitation stems from a fundamental trade‐off where the output voltage falls below the effective charging threshold, leaving the ultra‐low skin heat flux underexplored for physiological sensing. In this study, we report a skin‐interfaced wearable thermoelectric sensor and generator that synchronously harvests body high‐entropy energy and monitors deep tissue temperature (< 0.2°C). This dual functionality is enabled by a thermal meta‐design that guides inherently dispersed cutaneous heat flux into a vertical, one‐dimensional path through geometric confinement, ensuring signal fidelity for both sensing and energy conversion. To overcome the limited skin‐ambient temperature gradient, we introduce a reusable cooling hydrogel patch based on a dual‐mode evaporation mechanism, boosting the electrical output to 120 mV and power density to 45.7 μW cm –2 . Furthermore, during daily wear under an approximate 10 K skin‐environment temperature differential, the system achieved a sustained output of up to 34 mV. The integrated voltage boost‐storage circuit maintained the capacitor voltage at around 1.044 V, facilitating a sustainable power supply to electronic loads, and stabilized at approximately 5.2 V near full charge. The integrated system demonstrates continuous, multi‐parameter health monitoring powered solely by body heat. This research establishes a co‐design paradigm for concurrent deep body temperature monitoring and high‐entropy energy recovery, paving the way for self‐powered, multimodal integrated wearable devices.

Authors

Institutions

Publication Details

Journal
Carbon Energy
Published
2026-11-13
DOI
https://doi.org/10.1002/cey2.70399
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Skin‐Interfaced Wearable Device for Synchronically Harvesting High‐Entropy Body Energy and Monitoring Deep Tissue Temperature

Xiangyang Guo, Yongzheng Han, Rui Cui, Lin Qiu et al.
1 links
Carbon Energy
Advanced Sensor and Energy Harvesting Materials
article

Skin‐Interfaced Wearable Device for Synchronically Harvesting High‐Entropy Body Energy and Monitoring Deep Tissue Temperature

Xiangyang Guo, Yongzheng Han, Rui Cui, Lin Qiu, Xin Wang, Mingya Wang, Yanhui Feng
article en

Abstract

ABSTRACT Efficiently harvesting thermal energy from human skin poses formidable challenges owing to its high‐entropy characteristics. While Seebeck‐effect wearable thermoelectric devices can convert skin heat flux into electrical voltage, prevailing generators remain constrained in delivering sustainable energy and multifunctionality. This limitation stems from a fundamental trade‐off where the output voltage falls below the effective charging threshold, leaving the ultra‐low skin heat flux underexplored for physiological sensing. In this study, we report a skin‐interfaced wearable thermoelectric sensor and generator that synchronously harvests body high‐entropy energy and monitors deep tissue temperature (< 0.2°C). This dual functionality is enabled by a thermal meta‐design that guides inherently dispersed cutaneous heat flux into a vertical, one‐dimensional path through geometric confinement, ensuring signal fidelity for both sensing and energy conversion. To overcome the limited skin‐ambient temperature gradient, we introduce a reusable cooling hydrogel patch based on a dual‐mode evaporation mechanism, boosting the electrical output to 120 mV and power density to 45.7 μW cm –2 . Furthermore, during daily wear under an approximate 10 K skin‐environment temperature differential, the system achieved a sustained output of up to 34 mV. The integrated voltage boost‐storage circuit maintained the capacitor voltage at around 1.044 V, facilitating a sustainable power supply to electronic loads, and stabilized at approximately 5.2 V near full charge. The integrated system demonstrates continuous, multi‐parameter health monitoring powered solely by body heat. This research establishes a co‐design paradigm for concurrent deep body temperature monitoring and high‐entropy energy recovery, paving the way for self‐powered, multimodal integrated wearable devices.

Carbon Energy
Peking University Third Hospital (CN), University of Science and Technology Beijing (CN)
National Natural Science Foundation of China, Beijing Nova Program, Fundamental Research Funds for the Central Universities
Affordable and clean energy
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon