Development and evaluation of a microcapsule-based phantom simulating intra- and extracellular water diffusion

Abstract Objectives To develop a microcapsule-based phantom that simulates intra- and extracellular diffusion and to evaluate its microstructural validity using time-dependent diffusion-weighted imaging (DWI) metrics and limited spectrally edited diffusion (IMPULSED) modeling. Materials and methods Microcapsules with undecane cores and melamine resin membranes were fabricated in three diameter ranges and dispersed at different concentrations within an octane gel to create phantoms with controlled microstructure. DWI was performed using pulsed gradient spin-echo and oscillating gradient spin-echo research sequences with effective diffusion times of 5.8, 10.2, and 51.1 ms. Apparent diffusion coefficient (ADC), relative ADC (rADC), and incremental area under the curve (iAUC) were calculated. Microstructural parameters, including diameter, intracellular volume fraction ( f in ), intracellular diffusivity ( D in ), extracellular diffusivity ( D ex ), and cellularity were estimated using the IMPULSED model. Group differences were assessed using one-way ANOVA with Tukey’s post hoc test. Pearson’s correlation analysis was conducted to evaluate correlations between theoretical and estimated microstructural parameters. Reproducibility was assessed with Bland–Altman analysis according to repeated imaging of independently fabricated phantoms. Results ADC significantly decreased with increasing diffusion time in all microcapsule phantoms ( p < 0.001), whereas reference materials showed no time dependence. Higher microcapsule density resulted in lower ADC and higher rADC and iAUC. IMPULSED-derived diameters closely matched theoretical values ( r = 0.992). Estimated f in and cellularity strongly correlated with theoretical values ( r = 0.940 and 0.910). Reproducibility was good for ADC and IMPULSED-derived parameters. Conclusion This microcapsule-based phantom reproduces diffusion time-dependent restriction and enables quantitative validation of time-dependent DWI and IMPULSED-derived microstructural metrics. Key Points Question Validation of time-dependent diffusion MRI and microstructural models requires phantoms that reproduce both intra- and extracellular water diffusion under controlled conditions. Findings The microcapsule-based phantom reproduced diffusion-time-dependent restriction, and MRI-estimated diameters strongly correlated with theoretical diameters across tested conditions, with a Pearson correlation coefficient of 0.992. Relevance Statement The microcapsule-based phantom provides controlled intra- and extracellular diffusion environments for technical validation and standardization of quantitative MRI methods designed to characterize tissue microstructure.

Authors

Institutions

Publication Details

Journal
European Radiology Experimental
Published
2026-11-13
DOI
https://doi.org/10.1186/s41747-026-00849-1
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development and evaluation of a microcapsule-based phantom simulating intra- and extracellular water diffusion

Fumitaka Ejima, Masahiko Toyota, Thorsten Feiweier, Kiyohisa Kamimura et al.
1 links
European Radiology Experimental
Advanced Neuroimaging Techniques and Applications
article

Development and evaluation of a microcapsule-based phantom simulating intra- and extracellular water diffusion

Fumitaka Ejima, Masahiko Toyota, Thorsten Feiweier, Kiyohisa Kamimura, Hirokazu Otsuka, Tsubasa Nakano, Koji Takumi, Kazuya Sakoda, Takashi Yoshiura, Takashi Iwanaga, Hiroshi Imai
article en

Abstract

Abstract Objectives To develop a microcapsule-based phantom that simulates intra- and extracellular diffusion and to evaluate its microstructural validity using time-dependent diffusion-weighted imaging (DWI) metrics and limited spectrally edited diffusion (IMPULSED) modeling. Materials and methods Microcapsules with undecane cores and melamine resin membranes were fabricated in three diameter ranges and dispersed at different concentrations within an octane gel to create phantoms with controlled microstructure. DWI was performed using pulsed gradient spin-echo and oscillating gradient spin-echo research sequences with effective diffusion times of 5.8, 10.2, and 51.1 ms. Apparent diffusion coefficient (ADC), relative ADC (rADC), and incremental area under the curve (iAUC) were calculated. Microstructural parameters, including diameter, intracellular volume fraction ( f in ), intracellular diffusivity ( D in ), extracellular diffusivity ( D ex ), and cellularity were estimated using the IMPULSED model. Group differences were assessed using one-way ANOVA with Tukey’s post hoc test. Pearson’s correlation analysis was conducted to evaluate correlations between theoretical and estimated microstructural parameters. Reproducibility was assessed with Bland–Altman analysis according to repeated imaging of independently fabricated phantoms. Results ADC significantly decreased with increasing diffusion time in all microcapsule phantoms ( p < 0.001), whereas reference materials showed no time dependence. Higher microcapsule density resulted in lower ADC and higher rADC and iAUC. IMPULSED-derived diameters closely matched theoretical values ( r = 0.992). Estimated f in and cellularity strongly correlated with theoretical values ( r = 0.940 and 0.910). Reproducibility was good for ADC and IMPULSED-derived parameters. Conclusion This microcapsule-based phantom reproduces diffusion time-dependent restriction and enables quantitative validation of time-dependent DWI and IMPULSED-derived microstructural metrics. Key Points Question Validation of time-dependent diffusion MRI and microstructural models requires phantoms that reproduce both intra- and extracellular water diffusion under controlled conditions. Findings The microcapsule-based phantom reproduced diffusion-time-dependent restriction, and MRI-estimated diameters strongly correlated with theoretical diameters across tested conditions, with a Pearson correlation coefficient of 0.992. Relevance Statement The microcapsule-based phantom provides controlled intra- and extracellular diffusion environments for technical validation and standardization of quantitative MRI methods designed to characterize tissue microstructure.

European Radiology ExperimentalVol. 10(1)
Kagoshima University (JP), Fukushima Medical University (JP), Kagoshima University Hospital (JP), Siemens Healthineers (Germany) (DE), Siemens Healthcare K.K. (Japan) (JP)
Good health and well-being
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon