A Novel Double Kissing Nano Culotte Stenting for Coronary Bifurcation Lesions: A Detailed Technical Evaluation and Clinical Outcomes
BACKGROUND: Percutaneous coronary intervention (PCI) of coronary bifurcation lesions (CBL) remains one of the most technically demanding procedures in interventional cardiology, and the optimal two-stent stratgy has yet to be established. A technique that minimizes stent overlap while ensuring complete side branch osteal scaffolding may improve procedural and clinical outcomes. AIMS: Our aim in this study is to evaluate the feasibility, procedural performance, and 1-year clinical outcomes of the novel double kissing (DK) nano culotte technique for the treatment of CBL. METHODS: In this prospective, single-center observational study, 43 patients with true de novo CBLs underwent PCI using the DK nano-culotte technique, with OCT guidance used in 30 patients (69.7%). Eligible lesions had distal main-vessel and side-branch reference diameters ≥ 2.5 and ≥ 2.25 mm, respectively. Bench testing preceded first-in-human application, and computational fluid dynamics (CFD) analysis was performed. The primary endpoint was 1-year target lesion failure (TLF), defined as the composite of target lesion revascularization (TLR), target vessel myocardial infarction (TVMI), and cardiac death. RESULTS: Procedural and technical success were achieved in 100.0% and 97.6% of cases, respectively, with a mean procedure time of 48.0 ± 14.9 min. Residual diameter stenosis remained low across all treated segments, and no significant stent malapposition (> 500 μm) was identified by OCT. CFD demonstrated favorable post-procedural hemodynamic remodeling with significant improvement in time-averaged wall shear stress. At 1 year, TLF occurred in one patient (2.38%) owing to silent ischemia associated with in-stent restenosis requiring repeat revascularization. No TVMI, cardiac death, or stent thrombosis was observed. CONCLUSIONS: The DK nano culotte technique demonstrated excellent procedural feasibility, precise stent optimization, favorable flow dynamics, and encouraging 1-year clinical outcomes. These findings support further evaluation of this OCT-guided bifurcation strategy in larger multicenter studies (DK Nano-Culotte Stenting For Coronary Bifurcation Lesion; NCT05406284).
Authors
- Serkan Kahraman (ORCID: https://orcid.org/0000-0003-2796-0987)
- Onur Taşar (ORCID: https://orcid.org/0000-0003-2030-3810)
- Ali Kemal Kalkan (ORCID: https://orcid.org/0000-0003-3553-7468)
- Buğra Sarper (ORCID: https://orcid.org/0000-0001-7554-6575)
- Ahmet Taş (ORCID: https://orcid.org/0000-0002-1944-2576)
- Mehmet Ertürk (ORCID: https://orcid.org/0000-0002-2468-2793)
- Irem Türkmen (ORCID: https://orcid.org/0000-0003-1692-6417)
- Yaren Alan (ORCID: https://orcid.org/0000-0002-6204-2391)
- Ali Müftüoğulları (ORCID: https://orcid.org/0000-0002-9596-6101)
- Yusuf Yiğit Yılmaz (ORCID: https://orcid.org/0009-0005-7491-8580)
Institutions
- Acıbadem University (TR)
- Sağlık Bilimleri Üniversitesi (TR)
- Tarsus University (TR)
- Mehmet Akif Ersoy Göğüs Kalp ve Damar Cerrahisi Eğitim ve Araştırma Hastanesi (TR)
Publication Details
- Journal
- Catheterization and Cardiovascular Interventions
- Published
- 2026-11-13
- DOI
- https://doi.org/10.1002/ccd.71012
- Primary Topic
- Coronary Interventions and Diagnostics
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Türk Kardiyoloji Derneği