A High-Temperature Thermoelectric Generator Using a Venus Atmosphere Gradient: Couple Count and Output Sizing
This study sizes a High-Temperature Thermoelectric Generator Using a Venus Atmosphere Gradient for operation in the Venus surface environment and reports the result as SIMULATED, NOT MEASURED. The design is developed from stated physical relations and a shared environmental basis, and every performance figure is computed by the deposited script rather than asserted. Among the computed results are hot junction temperature of 980.0 kelvin, temperature difference across the couples of 235.0 kelvin, thermoelectric conversion efficiency of 0.0407 as a fraction, electric power output of 122.2 watts. Mass and power budgets are assembled from components so that they can be audited, off-design behaviour and materials uncertainty are discussed openly, and the limits of the sizing are stated in full. The system is a civilian science and construction design intended for a robotically serviced surface station.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-13
- DOI
- https://doi.org/10.5281/zenodo.24199483
- Citations
- 1
- Primary Topic
- Advanced Thermoelectric Materials and Devices
- Type
- article
- Field-Weighted Citation Impact
- 1.03