A Vapour-Compression Heat Pump Drawing on Subsurface Warmth for Lunar Night Habitat Heating
This study sizes a vapour-compression heat pump delivering 12 kilowatts of habitat heat through the lunar night from a subsurface source at 240 kelvin: the Carnot coefficient of performance is 5.36, the working coefficient at the stated second-law efficiency is 2.41, electrical demand is 4.97 kilowatts and ground extraction is 7.0 kilowatts. Sizing follows from computed thermal budgets derived in the study. This is a computed study with no targeting or weapon application. The work is simulated and computed from stated assumptions, not measured.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-13
- DOI
- https://doi.org/10.5281/zenodo.24189236
- Citations
- 1
- Primary Topic
- Refrigeration and Air Conditioning Technologies
- Type
- article
- Field-Weighted Citation Impact
- 1.57