Mechanical-thermal coupling analysis of a PEM fuel cell stack cooling loop under load transients: 1-D AMESim modeling and multi-parameter coordinated control

This paper investigates the transient thermal management of a proton exchange membrane fuel cell (PEMFC) stack cooling loop under variable-load conditions from a mechanical-thermal perspective. Existing control-oriented studies often treat coolant transport and radiator-side heat rejection separately, making it difficult to simultaneously address coolant temperature fluctuation, temperature-rise variation, and response delay during rapid load changes. To address this issue, a one-dimensional Advanced Modeling Environment for Performing Simulations of Engineering Systems (AMESim) model is developed for the cooling loop, including stack heat generation, intercooler thermal load, pump-driven coolant circulation, radiator-fan heat rejection, and large and small loop thermal branches. The thermal management problem is reformulated as a coordinated control problem for two main mechanical actuators, namely the electric water pump and cooling fan, while accounting for coolant thermal inertia, flow-dependent pressure loss, and radiator-fan coupling. Four control modes are comparatively studied: a baseline mode, a Δ T -based pump control mode, a flow-augmented fan control mode, and a coordinated pump-fan control mode. The results obtained under the selected transient load profile show that, relative to the baseline mode, the Δ T -based pump control improves the coolant-side temperature-rise behavior and reduces inlet and outlet coolant temperatures by about 0.4 °C and 0.9 °C, respectively. The flow-augmented fan control lowers coolant temperatures by about 2 °C after major load changes relative to the baseline mode. The coordinated control mode achieves the largest thermal improvement under the same transient profile, reducing inlet and outlet coolant temperatures by about 3 °C relative to the baseline mode while suppressing coolant-side temperature rise and fluctuation.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2026-11-14
DOI
https://doi.org/10.1016/j.egyr.2026.109813
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Mechanical-thermal coupling analysis of a PEM fuel cell stack cooling loop under load transients: 1-D AMESim modeling and multi-parameter coordinated control

Shijun Hu, Xingbang Wu
Energy Reports
Fuel Cells and Related Materials
article

Mechanical-thermal coupling analysis of a PEM fuel cell stack cooling loop under load transients: 1-D AMESim modeling and multi-parameter coordinated control

Shijun Hu, Xingbang Wu
article en

Abstract

This paper investigates the transient thermal management of a proton exchange membrane fuel cell (PEMFC) stack cooling loop under variable-load conditions from a mechanical-thermal perspective. Existing control-oriented studies often treat coolant transport and radiator-side heat rejection separately, making it difficult to simultaneously address coolant temperature fluctuation, temperature-rise variation, and response delay during rapid load changes. To address this issue, a one-dimensional Advanced Modeling Environment for Performing Simulations of Engineering Systems (AMESim) model is developed for the cooling loop, including stack heat generation, intercooler thermal load, pump-driven coolant circulation, radiator-fan heat rejection, and large and small loop thermal branches. The thermal management problem is reformulated as a coordinated control problem for two main mechanical actuators, namely the electric water pump and cooling fan, while accounting for coolant thermal inertia, flow-dependent pressure loss, and radiator-fan coupling. Four control modes are comparatively studied: a baseline mode, a Δ T -based pump control mode, a flow-augmented fan control mode, and a coordinated pump-fan control mode. The results obtained under the selected transient load profile show that, relative to the baseline mode, the Δ T -based pump control improves the coolant-side temperature-rise behavior and reduces inlet and outlet coolant temperatures by about 0.4 °C and 0.9 °C, respectively. The flow-augmented fan control lowers coolant temperatures by about 2 °C after major load changes relative to the baseline mode. The coordinated control mode achieves the largest thermal improvement under the same transient profile, reducing inlet and outlet coolant temperatures by about 3 °C relative to the baseline mode while suppressing coolant-side temperature rise and fluctuation.

Energy ReportsVol. 16
Lanzhou University of Technology (CN)
Affordable and clean energy
Fuel Cells and Related Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon