Standards Defining Echocardiography Core Laboratory (ECL) in Clinical Practice and Research.

Echocardiography is extensively utilized in both clinical practice and research due to its accessibility. Echocardiography core laboratories (ECLs) adhering to societal guidelines offer superior readings and interpretations compared with the on-site assessments by reducing measurement variability and enhancing study precision. In the present work, we aim to define minimum standards for clinical echocardiography laboratories and research ECLs based on recommendations from the American Society of Echocardiography and the European Association of Cardiovascular Imaging, as well as on expert opinion and our experience in European countries. Accurate acquisition of high-quality images is crucial for ensuring reproducibility, repeatability and reliability of the echocardiographic measurements. In addition to the commonly used workstations, an academic ECL must also possess the necessary capacities and skilled personnel to conduct sophisticated research projects. Personnel should hold advanced certification in echocardiography, indicating postgraduate training and experience beyond the basic cardiovascular ultrasound education. They should be capable of designing, performing, and interpreting complex echocardiography studies. Reproducibility of the ECL should be validated using a small, randomly selected sample, preferably in the early analytic phase. ECL readings and interpretations are superior to site-reported measurements and serve as the gold standard in observational studies and clinical trials. To ensure internal validity, an academic ECL should continuously evaluate/report reproducibility, repeatability and reliability. ECL should be formally acknowledged and accredited by an international scientific imaging society.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2026-11-12
DOI
https://doi.org/10.1093/ehjci/jeag317
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Standards Defining Echocardiography Core Laboratory (ECL) in Clinical Practice and Research.

Sahrai Saeed, Victoria Delgado, Erwan Donal, Denisa Muraru et al.
PubMed
Cardiovascular Function and Risk Factors
article

Standards Defining Echocardiography Core Laboratory (ECL) in Clinical Practice and Research.

Sahrai Saeed, Victoria Delgado, Erwan Donal, Denisa Muraru, Bogdan Alexandru Popescu, Thor Edvardsen
article en

Abstract

Echocardiography is extensively utilized in both clinical practice and research due to its accessibility. Echocardiography core laboratories (ECLs) adhering to societal guidelines offer superior readings and interpretations compared with the on-site assessments by reducing measurement variability and enhancing study precision. In the present work, we aim to define minimum standards for clinical echocardiography laboratories and research ECLs based on recommendations from the American Society of Echocardiography and the European Association of Cardiovascular Imaging, as well as on expert opinion and our experience in European countries. Accurate acquisition of high-quality images is crucial for ensuring reproducibility, repeatability and reliability of the echocardiographic measurements. In addition to the commonly used workstations, an academic ECL must also possess the necessary capacities and skilled personnel to conduct sophisticated research projects. Personnel should hold advanced certification in echocardiography, indicating postgraduate training and experience beyond the basic cardiovascular ultrasound education. They should be capable of designing, performing, and interpreting complex echocardiography studies. Reproducibility of the ECL should be validated using a small, randomly selected sample, preferably in the early analytic phase. ECL readings and interpretations are superior to site-reported measurements and serve as the gold standard in observational studies and clinical trials. To ensure internal validity, an academic ECL should continuously evaluate/report reproducibility, repeatability and reliability. ECL should be formally acknowledged and accredited by an international scientific imaging society.

PubMed
Oslo University Hospital (NO), Inserm (FR), Carol Davila University of Medicine and Pharmacy (RO), University of Oslo (NO), Haukeland University Hospital (NO), Institutul de Urgenţă pentru Boli Cardiovasculare "Prof.Dr. C.C. Iliescu" (RO), Laboratoire Traitement du Signal et de l'Image (FR), IRCCS Istituto Auxologico Italiano (IT), Hospital Universitari Germans Trias i Pujol (ES), Centre Hospitalier Universitaire de Rennes (FR), Université de Rennes (FR), University of Milano-Bicocca (IT)
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.