Seismic Analysis of Soft Story Frame High-Rise Building Using Shear Wall

This study compares the seismic response of three reinforced concrete models of a G+15 building in ETABS. Model 1 is a frame without shear walls. Model 2 adds corner shear walls, and Model 3 combines corner shear walls with soft storeys reported at ground, fifth, and tenth floors. The comparison uses base shear magnitudes, peak storey drift ratios, and roof displacements under separate linear static earthquake cases in the X and Y directions. The frame-only model produced 23.9606 mm of roof displacement and a peak drift ratio of 0.000640 in each direction. Model 2 produced the lowest roof displacements, 11.711 mm and 11.698 mm, and the lowest peak drift ratios, 0.000292 and 0.000291. Model 3 produced roof displacements of 12.834 mm and 12.837 mm and a peak drift ratio of 0.000309 in both directions. Relative to the frame-only model, Model 3 reduced roof displacement by 46.4% and peak drift by 51.7%. Its reported base shear was approximately 2.98 times the frame-only value. Conflicting zone labels and storey elevations in the model documentation limit code-specific interpretation.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-13
DOI
https://doi.org/10.5281/zenodo.24203774
Primary Topic
Seismic and Structural Analysis of Tall Buildings
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Seismic Analysis of Soft Story Frame High-Rise Building Using Shear Wall

Mohammed Mudassir Shaikh, Vishwanath Herimath
1 links
Zenodo (CERN European Organization for Nuclear Research)
Seismic and Structural Analysis of Tall Buildings
article

Seismic Analysis of Soft Story Frame High-Rise Building Using Shear Wall

Mohammed Mudassir Shaikh, Vishwanath Herimath
article en

Abstract

This study compares the seismic response of three reinforced concrete models of a G+15 building in ETABS. Model 1 is a frame without shear walls. Model 2 adds corner shear walls, and Model 3 combines corner shear walls with soft storeys reported at ground, fifth, and tenth floors. The comparison uses base shear magnitudes, peak storey drift ratios, and roof displacements under separate linear static earthquake cases in the X and Y directions. The frame-only model produced 23.9606 mm of roof displacement and a peak drift ratio of 0.000640 in each direction. Model 2 produced the lowest roof displacements, 11.711 mm and 11.698 mm, and the lowest peak drift ratios, 0.000292 and 0.000291. Model 3 produced roof displacements of 12.834 mm and 12.837 mm and a peak drift ratio of 0.000309 in both directions. Relative to the frame-only model, Model 3 reduced roof displacement by 46.4% and peak drift by 51.7%. Its reported base shear was approximately 2.98 times the frame-only value. Conflicting zone labels and storey elevations in the model documentation limit code-specific interpretation.

Zenodo (CERN European Organization for Nuclear Research)
Sustainable cities and communities
Seismic and Structural Analysis of Tall Buildings
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon