New 5-aminolevulinic acid fluorescence filter enhances glioma and background structure visualization: A controlled preclinical study

Background: The BLUE 400 S is a newly approved fluorescence filter for 5-aminolevulinic acid fluorescence- guided surgery that renders fluorescence as orange against a yellow-green background instead of the conventional color scheme of BLUE 400. Methods: Three orthotopic GL261 mouse gliomas were imaged under BLUE 400 and BLUE 400 S filters at four resection stages using both microscope camera and smartphone ocular photography. Four blinded reviewers measured the fluorescence dimension and rated boundary delineation confidence across eight pairs of images. Red-channel signal-to-background ratio (SBR) was computed from fixed-coordinate regions-of- interest. Widefield fluorescence imaging was correlated with conventional histology and in vivo confocal laser endomicroscopy (CLE) imaging. Results: BLUE 400 S provided a brighter, anatomically richer operative field across all stages. Tumor fluorescence was clearly delineated under both filters. Interrater reliability was excellent across all imaging conditions. Fluorescence dimension measurements did not differ between filters, but boundary-delineation confidence was higher under BLUE 400 S despite lower red-channel SBR. The digital camera amplified apparent fluorescence brightness and contrast relative to the ocular view at the cost of reduced internal texture within positive fluorescence and background details. CLE and histology confirmed graded correspondence between fluorescence intensity and tumor cellularity. Conclusion: BLUE 400 S improved visualization of background anatomy and rater confidence in fluorescence boundary determination while maintaining equivalent tumor fluorescence dimension measurements. These findings support its perceptual advantage over conventional BLUE 400 and should be further evaluated clinically.

Authors

Publication Details

Journal
Surgical Neurology International
Published
2026-11-13
DOI
https://doi.org/10.25259/sni_825_2026
Primary Topic
Glioma Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

New 5-aminolevulinic acid fluorescence filter enhances glioma and background structure visualization: A controlled preclinical study

Yuan Xu, Mark C. Preul, Zachary Comella, Jaden Wise et al.
1 links
Surgical Neurology International
Glioma Diagnosis and Treatment
article

New 5-aminolevulinic acid fluorescence filter enhances glioma and background structure visualization: A controlled preclinical study

Yuan Xu, Mark C. Preul, Zachary Comella, Jaden Wise, Katelyn C. John, Nicholas Postell
article en

Abstract

Background: The BLUE 400 S is a newly approved fluorescence filter for 5-aminolevulinic acid fluorescence- guided surgery that renders fluorescence as orange against a yellow-green background instead of the conventional color scheme of BLUE 400. Methods: Three orthotopic GL261 mouse gliomas were imaged under BLUE 400 and BLUE 400 S filters at four resection stages using both microscope camera and smartphone ocular photography. Four blinded reviewers measured the fluorescence dimension and rated boundary delineation confidence across eight pairs of images. Red-channel signal-to-background ratio (SBR) was computed from fixed-coordinate regions-of- interest. Widefield fluorescence imaging was correlated with conventional histology and in vivo confocal laser endomicroscopy (CLE) imaging. Results: BLUE 400 S provided a brighter, anatomically richer operative field across all stages. Tumor fluorescence was clearly delineated under both filters. Interrater reliability was excellent across all imaging conditions. Fluorescence dimension measurements did not differ between filters, but boundary-delineation confidence was higher under BLUE 400 S despite lower red-channel SBR. The digital camera amplified apparent fluorescence brightness and contrast relative to the ocular view at the cost of reduced internal texture within positive fluorescence and background details. CLE and histology confirmed graded correspondence between fluorescence intensity and tumor cellularity. Conclusion: BLUE 400 S improved visualization of background anatomy and rater confidence in fluorescence boundary determination while maintaining equivalent tumor fluorescence dimension measurements. These findings support its perceptual advantage over conventional BLUE 400 and should be further evaluated clinically.

Surgical Neurology InternationalVol. 17
Good health and well-being
Glioma Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon