Surface roughness evaluation after orthodontic adhesive cleanup using fluorescence-aided identification technique and different burs: A SEM analysis
Background : Complete removal of adhesive remnants after orthodontic debonding is essential to prevent enamel damage, discoloration, plaque retention, and long-term periodontal complications. Conventional rotary instruments may compromise enamel integrity during cleanup procedures. Fluorescence-aided identification technique (FIT), used with fluorescent orthodontic composites, offers enhanced visualization of orthodontic adhesive and may improve cleanup outcomes. This study aimed to evaluate the efficacy of FIT compared with conventional illumination using different rotary instruments. Materials and Methods : Seventy-two extracted premolars were randomly allocated into six groups (n = 12) based on the type of orthodontic adhesive —fluorescent composite (Maquira Fix) or conventional composite (Transbond XT)—and cleanup instrument (12-fluted tungsten carbide bur, 30-fluted tungsten carbide bur, or composite finishing bur). Adhesive cleanup was performed under either fluorescent or conventional illumination. The time required for adhesive removal was recorded, and enamel surfaces were examined using scanning electron microscopy (SEM) at 200 × magnification. Surface roughness was assessed using the Modified Surface Roughness Index (SRI). Statistical analysis was performed with the level of significance set at p < 0.05. Results : The smoothest enamel surfaces were observed in groups cleaned using a 30-fluted tungsten carbide bur, irrespective of the type of orthodontic composite used, with the lowest surface roughness index (SRI = 1). No difference in SRI scores was observed between fluorescent and conventional composites for the same bur type. The shortest cleanup time was recorded in groups cleaned under fluorescent illumination, particularly when using tungsten carbide burs. Groups using composite finishing burs required significantly longer cleanup time and demonstrated higher surface roughness scores. Qualitative SEM observations supported these findings, demonstrating smoother enamel morphology with the use of 30-fluted tungsten carbide burs. Conclusion : Fluorescence-aided identification technique improves visualization during orthodontic adhesive cleanup and significantly reduces cleanup time. However, enamel surface roughness is primarily influenced by the type of rotary instrument used rather than the composite type. The use of a 30-fluted tungsten carbide bur provides superior enamel surface preservation, while fluorescent illumination enhances procedural efficiency. This combination represents a clinically effective approach for post-debonding adhesive removal.
Authors
- Anil Kumar Chandna (ORCID: https://orcid.org/0000-0002-7109-0547)
- Mathew Koshy Vaidyan (ORCID: https://orcid.org/0000-0003-0962-236X)
- Anshul Singla (ORCID: https://orcid.org/0000-0001-9095-3697)
- Shyam Sivasamy (ORCID: https://orcid.org/0000-0003-0923-499X)
- Apoorva Gupta (ORCID: https://orcid.org/0009-0001-8378-4888)
- Amrita Puri (ORCID: https://orcid.org/0000-0003-0755-1166)
Institutions
- Meenakshi Ammal Dental College and Hospital (IN)
Publication Details
- Journal
- Journal of Dental Specialities
- Published
- 2026-11-13
- DOI
- https://doi.org/10.18231/j.jds.14787.1772795482
- Primary Topic
- Orthodontics and Dentofacial Orthopedics
- Type
- article
- Field-Weighted Citation Impact
- 0.00