Physics-Based Calibration of the Fiber Bragg Grating Temperature Response via Particle Swarm Optimization

Fiber Bragg grating (FBG) sensors are widely used for temperature monitoring because of their compact size, wavelength-encoded response, corrosion resistance, multiplexing capability, and immunity to electromagnetic interference. However, the accuracy of physics-based FBG models depends strongly on the thermal and optical parameters adopted in the simulation. This study developed a MATLAB-based physics-driven framework for calibrating the temperature response of a uniform silica FBG using particle swarm optimization (PSO). The model was formulated from the Bragg condition and incorporated temperature-dependent variations in effective refractive index and grating period through the thermo-optic and thermal-expansion coefficients. A published 17-point temperature–wavelength dataset spanning approximately 9.49–90.34 °C was digitized for model calibration and comparison. The extracted experimental sensitivity was 9.9450 pm/°C, compared with 10.13 pm/°C reported in the source study. The baseline model predicted a sensitivity of 14.1799 pm/°C, with RMSE, MAE, MAPE, and R² values of 0.20353 nm, 0.17446 nm, 43.90%, and 0.3151, respectively. Following PSO calibration, the predicted sensitivity decreased to 9.8888 pm/°C, differing by only 0.57% from the extracted experimental value. The calibrated model achieved an RMSE of 0.00521 nm, MAE of 0.00405 nm, MAPE of 1.38%, and R² of 0.99955. These results demonstrate that bounded PSO calibration can substantially improve agreement between a transparent physics-based FBG model and experimental data. Because the same dataset was used for parameter estimation and performance assessment, the results represent in-sample calibration performance rather than independent predictive validation.

Authors

Institutions

Publication Details

Journal
International Journal Of Scientific Research In Engineering & Technology
Published
2026-11-13
DOI
https://doi.org/10.59256/ijsreat.20260606021
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Physics-Based Calibration of the Fiber Bragg Grating Temperature Response via Particle Swarm Optimization

Sahabi Abubakar, Mikailu Kabiru Yahaya, Bin Jalil Muhammad Arif
2 links
International Journal Of Scientific Research In Engineering & Technology
Advanced Fiber Optic Sensors
article

Physics-Based Calibration of the Fiber Bragg Grating Temperature Response via Particle Swarm Optimization

Sahabi Abubakar, Mikailu Kabiru Yahaya, Bin Jalil Muhammad Arif
article en

Abstract

Fiber Bragg grating (FBG) sensors are widely used for temperature monitoring because of their compact size, wavelength-encoded response, corrosion resistance, multiplexing capability, and immunity to electromagnetic interference. However, the accuracy of physics-based FBG models depends strongly on the thermal and optical parameters adopted in the simulation. This study developed a MATLAB-based physics-driven framework for calibrating the temperature response of a uniform silica FBG using particle swarm optimization (PSO). The model was formulated from the Bragg condition and incorporated temperature-dependent variations in effective refractive index and grating period through the thermo-optic and thermal-expansion coefficients. A published 17-point temperature–wavelength dataset spanning approximately 9.49–90.34 °C was digitized for model calibration and comparison. The extracted experimental sensitivity was 9.9450 pm/°C, compared with 10.13 pm/°C reported in the source study. The baseline model predicted a sensitivity of 14.1799 pm/°C, with RMSE, MAE, MAPE, and R² values of 0.20353 nm, 0.17446 nm, 43.90%, and 0.3151, respectively. Following PSO calibration, the predicted sensitivity decreased to 9.8888 pm/°C, differing by only 0.57% from the extracted experimental value. The calibrated model achieved an RMSE of 0.00521 nm, MAE of 0.00405 nm, MAPE of 1.38%, and R² of 0.99955. These results demonstrate that bounded PSO calibration can substantially improve agreement between a transparent physics-based FBG model and experimental data. Because the same dataset was used for parameter estimation and performance assessment, the results represent in-sample calibration performance rather than independent predictive validation.

International Journal Of Scientific Research In Engineering & Technology
University of Technology Malaysia (MY)
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon